Titan High-Pressure Fluid Filtration · PowrCoat 730
Find Diagram-Matched PowrCoat 730 High-Pressure Filter Parts
Shop verified components for the PowrCoat 730 High Pressure Filter, including the 0290423A filter cap, 920-004 50-mesh element, thick and thin PTFE gaskets, 808-555 fitting, two documented pipe plugs, 0290424A filter body, and 920-103 stainless ball. Match the official diagram position and exact Titan part number before ordering.
How the PowrCoat 730 High-Pressure Filter Protects the Spray System
This page is an exploded replacement-parts category for the PowrCoat 730 high-pressure fluid-filter assembly. Pressurized coating enters the filter body, passes through the 50-mesh element from the inside out, and exits through the connected outlet path toward the spray hose, gun, and tip.
The filter cap retains the element and compresses the thin and thick PTFE gaskets. The stainless ball is installed with the element, while the fitting and two specified pipe plugs complete the documented PowrCoat 730 port configuration.
Functions Supported by the Filter Assembly
- Captures coating debris before it reaches downstream spray components.
- Supports cleaner spray patterns and reduces avoidable tip plugging.
- Contains high-pressure coating inside the cap and filter body.
- Seals the cap-to-body interface with two PTFE gaskets.
- Provides documented outlet and plugged-port positions for the PowrCoat 730.
When Contractors Use This Filter Diagram
- Poor spray pattern or repeated spray-tip blockage.
- Reduced coating flow after hose, gun, and tip checks.
- Leakage around the filter cap or gasket stack.
- Damaged element, scratched internal ball, or contaminated housing.
- Loose, incorrect, damaged, or leaking filter fittings and plugs.
Common PowrCoat 730 High-Pressure Filter Symptoms
Diagnose coating viscosity, suction condition, pump output, hose, gun filter, spray tip, and pressure settings before replacing filter components. Fully relieve system pressure before opening the housing.
High-Value PowrCoat 730 Filter Parts
These verified products cover every numbered component shown on the supplied PowrCoat 730 high-pressure-filter page.
Titan 0290423A Filter Cap
Closes the high-pressure filter housing, retains the element, and compresses the sealing gaskets against the filter body.
Titan 920-004 Filter Element, 50 Mesh
The documented 50-mesh filter element for the PowrCoat 730 high-pressure filter, reducing debris before coating reaches the hose, gun, and tip.
Titan 920-006 Thick PTFE Gasket
The thick PTFE gasket installed above the thin gasket to support reliable cap sealing and pressure containment.
Titan 920-070 Thin PTFE Gasket
The thin PTFE gasket seated on the filter-body step beneath the thick gasket during correct reassembly.
Titan 808-555 Hex Fitting, 3/8 Inch
The documented 3/8-inch hex fitting used at the PowrCoat 730 high-pressure filter assembly.
Titan 227-033 Pipe Plug
Closes unused filter-body ports and helps retain pressurized coating within the documented filter configuration.
Titan 0290424A Filter Body
Houses the filter element, ball, gaskets, fittings, and plugs while containing pressurized coating material.
Titan 227-027 Pipe Plug
Seals the additional documented filter-body opening used on the PowrCoat 730 configuration.
Titan 920-103 Stainless Ball, 13/16 Inch
The documented stainless ball installed with the filter element and inspected for pressure cuts or scratches during service.
How to Select the Correct Filter Component
Identify the failure area
Separate filtration restriction, cap sealing, body damage, ball wear, fitting leakage, and plug leakage.
Match the exact callout
Use positions 1 through 9 and confirm the exact Titan part number.
Inspect mating parts
Check cap, body, both gaskets, element, ball, fittings, plugs, and threads together.
Confirm system causes
Verify coating condition, pump output, gun filter, hose, and tip before replacing the housing.
Maintenance Practices That Protect the Filter Assembly
- Clean the high-pressure filter regularly and whenever spray performance declines.
- Clean the element thoroughly from the inside because it filters from the inside out.
- Soak hardened coating in an appropriate solvent or replace the element.
- Inspect the 920-103 ball for pressure cuts and scratches.
- Inspect both PTFE gaskets for deformation, nicks, cuts, and hardened coating.
- Protect cap and body threads from cross-threading, impact, dirt, and dried material.
Build a Complete PowrCoat 730 Filter Repair
Cap and sealing service should inspect the 0290423A cap, 920-006 thick gasket, 920-070 thin gasket, 0290424A body step, cap threads, body threads, and dried coating contamination as one sealing system.
Flow-path service should inspect the 920-004 element, 920-103 ball, body passages, 808-555 fitting, 227-033 plug, 227-027 plug, hose outlet, spray gun, gun filter, and tip. Replacing one component will not correct coating contamination or an obstruction elsewhere in the system.
Shop Major PowrCoat 730 High-Pressure Filter Components
PowrCoat 730 High-Pressure Filter FAQs
Verified answers for filter identification, cleaning, gasket installation, troubleshooting, replacement planning, and safe service.