OEM Titan PTFE Gasket

Titan 920-006 Gasket is an OEM PTFE (Teflon) gasket that provides a reliable, chemical-resistant seal in the outlet manifold filter assembly on compatible PowrTwin, PowrLiner, PowrCoat, and PowrBeast sprayer models.

Brand: Titan Part #: 920-006 Type: PTFE Gasket Thickness: Thick

Compatibility Overview

Brand Compatible Series Part Number Function
Titan PowrTwin, PowrLiner, PowrCoat, PowrBeast, PowrTex, Admiral, Epic 920-006 Manifold filter assembly sealing

PTFE construction provides exceptional chemical resistance to paints, solvents, and aggressive fluids while maintaining reliable sealing under pressure. A worn, crushed, or hardened gasket causes fluid leaks at the filter block, pressure loss, and potential contamination. OEM replacement restores proper sealing and filtration system integrity.

Quantity
Buy Now
Genuine OEM Part Fast Shipping Easy Returns

Titan Filter Block Gasket Replacement

Titan 920-006 Gasket for Outlet Manifold Filter Assembly

Titan 920-006 is an OEM PTFE (Teflon) gasket designed for the outlet manifold filter assembly on compatible Titan airless sprayers. Listed as "Gasket, PTFE (thick)" in the official Titan 1200GXC manual and the PowrTwin 3500 manual, this critical sealing component ensures a leak-free connection between the pump and the filter block. The gasket is also included in the Filter Service Kit 930-050, making it a standard replacement item during filter maintenance. PTFE construction provides exceptional chemical resistance to paints, solvents, and hydraulic fluids while maintaining reliable sealing under pressure. It is documented for use across a wide range of Titan models including the 1100XC, 1200GXC, PowrTwin 3500, PowrLiner 9900XLT, and numerous PowrLiner, PowrCoat, PowrBeast, PowrTex, Admiral, and Epic series sprayers. Over time, gaskets can become crushed, hardened, or damaged during filter service, leading to fluid leaks at the filter block, pressure loss, and potential contamination. Titan recommends replacing the gasket between the pump and the filter block during service. This genuine OEM gasket ensures correct fitment and reliable sealing for professional painting contractors and maintenance programs.

OEM: Titan Part #: 920-006 Type: PTFE Gasket Thickness: Thick
Detail Technical / Commercial Information
Product Overview OEM Titan PTFE (Teflon) gasket for the outlet manifold filter assembly. Provides a chemical-resistant, leak-free seal between the pump and filter block.
Function Seals the connection between the pump outlet and the filter block. PTFE material resists paints, solvents, and aggressive fluids while maintaining reliable sealing under pressure. Included in Filter Service Kit 930-050.
System Location Outlet manifold filter assembly. Listed as item 9 "Gasket, PTFE (thick)" in the 1200GXC Filter Block Assembly and item 4 in the PowrTwin 3500 930 Outlet Manifold Filter Assembly.
Documented Compatible Models Titan 1100XC; 1200GXC; 1200HPG; PowrTwin 3500/3500-DC/4500/4900GH/4900XLT/5500/6900GH/12000GH/12000GHD/12000XLT/12000XLTDI; PowrLiner 4000/4900/4950/4955/5000/6000/6900/6900XLT/6950/6955/9900XLT; PowrCoat 730/745/940/960/975; PowrBeast 4700T/4700; PowrTex 6900SF/12000SV/1200SV; Epic 1200HPG. Verify your exact model against the parts diagram.
OEM Part Number 920-006 Gasket, PTFE (thick).
Common Problems Solved Fluid leaks at the filter block, pressure loss, contamination ingress, and compromised filtration system integrity caused by a crushed, hardened, or damaged gasket.
Replacement Indicators Visible fluid weeping at the filter block, gasket shows signs of crushing, hardening, or damage. Titan recommends replacing the gasket during filter service.
Related Parts Commonly Serviced Together Filter element 50 mesh (920-004), 100 mesh (920-005), 5 mesh (920-001); thin PTFE gasket (920-070); filter cap (920-917); check valve (940-553); O-ring and spring included in Filter Service Kit 930-050.
Installation Notes Always relieve system pressure before servicing. Inspect the gasket for deformity, nicks, or cuts. Replace as required. Clean sealing surfaces before installation.

The 920-006 Gasket is a critical sealing component in the outlet manifold filter assembly. Titan recommends replacing the gasket between the pump and filter block during filter service. If you observe fluid weeping at the filter block or pressure loss that persists after filter element replacement, inspect the gasket for crushing, hardening, or damage. This genuine OEM PTFE gasket ensures reliable sealing and chemical resistance for professional painting contractors.

Frequently Asked Questions

Contractor-focused answers for confirming fitment and service value.

Common Questions
What is the Titan 920-006 Gasket used for?

It seals the outlet manifold filter assembly, providing a chemical-resistant, leak-free connection between the pump and filter block.

Which Titan sprayers use part 920-006?

It is documented for 1100XC, 1200GXC, PowrTwin 3500 through 12000 series, PowrLiner 4000 through 9900XLT series, PowrCoat 730 through 975, PowrBeast 4700, PowrTex 6900SF/12000SV, and Epic 1200HPG models. Always verify your exact model against the parts diagram.

What is the difference between 920-006 and 920-070?

The 920-006 is the thick PTFE gasket, while the 920-070 is the thin PTFE gasket. Both are used in the filter assembly and are included in Filter Service Kit 930-050.

When should the gasket be replaced?

Replace whenever the filter assembly is serviced, or when you observe fluid weeping at the filter block, gasket crushing, hardening, or visible damage.

What related parts should be inspected when replacing the gasket?

Inspect the filter element, thin PTFE gasket (920-070), filter cap, check valve, and O-ring. Replace any worn components during the service.