Genuine Titan OEM | Valve Assembly Replacement Parts
Shop Titan Performer 1140ix PRIME-SPRAY Valve Assembly Parts
Find the replacement components your repair requires with Titan Performer 1140ix PRIME-SPRAY Valve Assembly Parts from AllTitanParts. Browse genuine OEM parts by diagram reference and part number, then select the components that match your sprayer and service needs.
Assembly Overview
Choose Replacement Parts for Your PRIME-SPRAY Valve Repair
The PRIME-SPRAY valve controls fluid routing between priming and spraying. A valve that does not operate or seal correctly can interfere with normal sprayer operation. Careful inspection helps determine whether the problem involves the valve mechanism, sealing components or another part of the fluid system.
Select replacement parts after identifying the fault. Matching the component to its diagram position helps distinguish similar-looking seals and hardware, while checking the exact part number reduces ordering errors.
OEM Parts Directory
Titan Performer 1140ix PRIME-SPRAY Valve Assembly Parts List
Use the following directory alongside the exploded drawing to identify the required component.
| Diagram Ref. | Titan Part Number | Component |
|---|---|---|
| 1 | 700-823 | Dowel Pin |
| 2 | 700-537 | Gasket |
| 3 | 222-012 | PTFE O-Ring |
| 4 | 221-012 | Viton O-Ring |
| 5 | 700-253 | Bypass Valve Housing |
| 6 | 800-910 | Bypass Valve Seat |
| 7 | 700-697 | Valve Handle |
| 8 | 700-759 | Groove Pin |
| 9 | 700-721 | O-Ring |
| 11 | 800-926 | Spring |
| 12 | 700-248 | Bypass Valve Retainer |
| 13 | 700-251 | Bypass Cam Base, replaces Titan 0507735 |
Reference 10 is not included in the displayed product list. Confirm any unlisted component before ordering.
Repair Component Selection
Inspect Seals, Valve Surfaces and Operating Hardware
Seals and Gasket
Inspect sealing components for cuts, deformation and other damage during service. Choose replacements by their specified part numbers and locations. Similar appearance does not establish interchangeability.
Housing and Valve Seat
Check accessible valve surfaces and connections according to the service instructions. Wear, contamination or physical damage may affect sealing, but diagnosis should establish the cause before parts are replaced.
Handle and Pins
Inspect the operating hardware if the handle is loose, damaged or difficult to move. Do not force a sticking mechanism. Follow the specified inspection and assembly procedure.
Spring, Retainer and Cam
Check mechanical components for damage and correct placement. Preserve the intended assembly order and use the designated replacement rather than substituting general-purpose hardware.
Before You Order
Match Your Repair to the Correct Replacement
- Confirm the model. Record the sprayer's model and serial information.
- Diagnose the fault. Priming difficulties can also involve suction leaks, intake restrictions or pump problems.
- Check the drawing. Match the component's location and part number to the assembly diagram.
- Review the product. Confirm the description, replacement references and required quantity before checkout.
Preventive Maintenance
Keep the Valve Clean and Ready for Service
Follow the manufacturer's flushing and storage instructions to limit dried coating buildup in the fluid system. Use cleaning materials appropriate for the coating and equipment, and avoid forcing the valve handle if movement becomes restricted.
During scheduled service, inspect the assembly for damaged seals, worn components and loose operating hardware. Address the cause of a recurring fault before returning the sprayer to use.
Related Parts Categories
Explore More Performer 1140ix Parts
Relieve System Pressure Before Valve Service
Switch off the sprayer, disconnect electrical power and follow Titan's complete pressure-relief procedure before removing valve components. Do not assume that switching off the equipment eliminates trapped pressure. Never loosen a pressurized connection or use your hand to stop a fluid leak. Follow the manufacturer's instructions for installation and restart.
Find Your Replacement Component
Order Performer 1140ix PRIME-SPRAY Valve Parts
Identify the required component, compare its part number and shop your replacement online.
Shop PRIME-SPRAY Valve Assembly PartsFrequently Asked Questions
PRIME-SPRAY Valve Assembly FAQ
Is this category a complete valve kit?
This page is a directory of individual replacement components. Review the selected product's description to determine exactly what is included with your purchase.
How do I choose the correct valve component?
Confirm your sprayer model, identify the component in the exploded drawing and match its part number. Check replacement references and product details before ordering.
Does a priming problem always mean the valve needs replacement?
No. Suction leaks, restricted intake components and pump faults can also prevent priming. Follow the manufacturer's troubleshooting procedure to identify the cause.
Can I substitute an O-ring that looks the same?
Appearance alone does not confirm suitability. Seal dimensions, material and installation location matter. Use the specified replacement for the designated position.
What should I do if the valve handle is difficult to move?
Do not force it. Shut down the equipment, complete the pressure-relief procedure and follow Titan's inspection instructions to determine whether contamination or mechanical damage is involved.
What information should I provide when requesting fitment help?
Provide the model, serial number, diagram reference and existing part number. A clear photograph of the component can also help with identification.
Parts Identification Assistance
Need Help Choosing Your Valve Assembly Part?
Have your model information and diagram reference ready when contacting AllTitanParts.
713-931-0006








