Please wait while we process your order...

Link copied!
Genuine OEM Parts For
Titan, SpeeFlo, SprayTech & Wagner Authorized Titan Dealer Fitment help: (713) 931-0006 30-Day Return Window (RMA Required)
In Short

Check the simplest things first: a worn tip, a clogged filter or inlet screen, an air leak on the suction side, and the PRIME/SPRAY valve left in SPRAY. Then look at a stuck inlet valve, worn valve balls or seats, and worn packings. Titan's Impact 640 and 1040 manuals use this same order. Relieve pressure before you open anything.

The order below is the one Titan's Impact 640 and 1040 manuals use in their troubleshooting tables, and the logic is the same across Titan's Impact manuals. Those two manuals were read for this guide, and the Impact X 410 manual excerpt agrees on the no-prime causes. Your own Impact X manual has the table for your model, and it is on our manuals page.

Relieve pressure firstAirless pressure can inject paint through the skin, and that is a medical emergency. Before you check a filter, a fitting or any part, follow the pressure relief procedure in your sprayer's manual. This guide points you to parts and checks. It does not replace the manual's repair steps.

Start with the tip and the strainers

A worn tip has a wider orifice, so pressure falls and the pattern gets coarse. The manuals also list a clogged pump filter, gun filter or inlet screen among the causes of low pressure and poor patterns. These are the simplest checks, so do them first.

  • Spray tip: replace it if the pattern has degraded.
  • Pump filter: the 60 mesh 2424933 on the Filter Assembly page.
  • Inlet screen filter: 700-805 on the Suction Set page.
  • Gun filter, if your gun has one.

Check for an air leak on the suction side

An air leak at the siphon tube or suction set connection stops the pump drawing paint, so it will not prime or will lose pressure. The manuals say to tighten the connection or re-tape it with PTFE tape. If the parts are damaged, the Suction Set Assembly page lists siphon tube assembly 2426336, O-ring 9871105 and retaining clip 9822526. The Impact X 410 and 540I have matching Suction Set pages.

Is the inlet valve stuck?

The Impact X 410 manual excerpt lists two causes of a sprayer that will not prime: the PRIME/SPRAY valve left in SPRAY, and a stuck inlet valve. Turn it to PRIME first. For a stuck inlet valve, the manuals describe using the pusher stem. The site lists pusher stem assemblies on the Main Assembly pages, 2423817A on the Impact X 440 and 2423819A on the Impact X 540I, and a pusher stem clip, 2423825. If the valve itself is worn, the 805-846 inlet valve kit is the replacement.

Valves and seats

If the sprayer will not hold pressure and the checks above are clear, the manuals point to an internal leak in the fluid section: worn or dirty packings, or worn valve balls. They say to clean the valves and service the fluid section, and to reverse or replace worn seats when fluid leaks at the top of the fluid section. Titan's manuals describe the steps. The parts are on the fluid section pages:

Impact X fluid section valve parts

PartNumberWhere
Inlet valve ball762-145X 410, X 440, X 540I fluid section pages
Outlet valve ball50164Same pages
Foot valve seat762-137Same pages
Outlet valve seat704-558Same pages
Inlet valve cage704-703Same pages
Outlet valve kit805-845Accessories pages; fitment names the X 410, 440 and 540I

Pages: Impact X 410 Fluid Section, Impact X 440 Fluid Section Assembly and Impact X 540I Fluid Section Assembly.

Packings and pulsing

Surging or pulsing at the gun is listed in the manuals as a sign of worn upper packings. Packings seal the moving piston rod, so a leak past them also shows as fluid at the top of the fluid section or paint where it should not be. On the Impact X 440 and X 540I pages the repacking kit is 704-586B. The piston rod is 2420579A and the piston assembly is 2420580A. A scored rod damages new packings, so inspect it when you repack. We do not list kit contents here, so check the diagram or call before you buy.

When it is not the pump

If the unit will not run at all, Titan's manual lists causes such as a tripped breaker, the pressure knob at minimum, loose wiring and a defective switch. Loose wiring is a job for a Titan service center. The diagram shows the electrical parts: potentiometer 2423449, fuse 800-929, power switch 2420453 and transducer 2427607A. Do not replace them by guesswork. Follow the manual or call (713) 931-0006 with your model and serial number.

Parts mentioned in this troubleshooting path:

Titan 805-846 Inlet Valve Kit −10%
Titan
Titan 805-846 Inlet Valve Kit
Part #: 805-846
$118.99 $132.80 Save $13.81
Buy Now
Titan 805-845 Outlet Valve Kit −8%
Titan
Titan 805-845 Outlet Valve Kit
Part #: 805-845
$52.09 $56.80 Save $4.71
Buy Now
Titan 704-586B Repacking Kit −8%
Titan
Titan 704-586B Repacking Kit
Part #: 704-586B
$84.91 $92.60 Save $7.69
Buy Now
Titan 2423817A Pusher Stem Assembly −8%
Titan
Titan 2423817A Pusher Stem Assembly
Part #: 2423817A
$63.82 $69.60 Save $5.78
Buy Now
Titan 2424933 Filter 60 Mesh #1 Seller
Titan
Titan 2424933 Filter 60 Mesh
Part #: 2424933
$18.30
Buy Now
Titan 700-805 Inlet Screen Filter −8%
Titan
Titan 700-805 Inlet Screen Filter
Part #: 700-805
$24.56 $26.74 Save $2.18
Buy Now
Titan 50164 Outlet Valve Ball Genuine OEM
Titan
Titan 50164 Outlet Valve Ball
Part #: 50164
$3.80
Buy Now

The Short Version

Tip, filters, suction leak, then the PRIME/SPRAY valve and inlet valve. After that, balls and seats, and finally packings. Replace in that order of cost, and use the fluid section page for your exact model: Impact X 410, Impact X 440 or Impact X 540I.

Still losing pressure?

Call (713) 931-0006 with your Impact X model and what the sprayer is doing, and our parts team will point you to the right diagram.

(713) 931-0006Order by Parts Diagram
Frequently Asked Questions
Why won't my Impact X build pressure?
Titan's manuals list a worn tip, an air leak, a clogged filter or screen, or an internal fluid section leak from worn packings or valve balls. Start with the tip and filters, then check the suction side, then the valves and packings.
Why does my Impact X pulse at the gun?
Titan's Impact manuals list surge or pulsing at the gun as a sign of worn upper packings. A partly blocked filter can also cause pulsing, so clean the filters first. The repacking kit on the Impact X 440 and 540I pages is 704-586B.
My Impact X won't prime: what do I check?
Per the Impact X 410 manual excerpt, check that the PRIME/SPRAY valve is set to PRIME and that the inlet valve is not stuck. Also look for an air leak at the siphon tube and a clogged filter or screen.
How do I know the valves are worn?
The manuals point to worn valve balls or seats when the sprayer will not hold pressure and the tip, filters and suction side are fine. Open the fluid section as the manual describes, and compare with the fluid section diagram.
Which Impact X parts are in the repacking kit?
We do not list the kit's contents here. The 704-586B repacking kit appears on the Impact X 440 and X 540I fluid section pages. Call (713) 931-0006 to confirm the contents before you order.
On this page

Added to cart

Your Cart
No items in cart.
Add more items
Total 0
Checkout Modify Cart