In Short

Relieve pressure and unplug. Push the groove pin out of the valve handle, lift off the handle and cam base, and unscrew the valve housing assembly from the pump block with a wrench. Thread in the new 700-258 housing with its gasket in place, tighten it, grease the cam base and line its cam up with the pump block, then pin the handle back through the valve stem and test in PRIME and SPRAY.

The PRIME/SPRAY valve (Titan's PrimeSpray valve) decides where the pump sends paint: down the return hose while you prime, or out to the gun when you spray. It is also the part that bleeds the pump during pressure relief. The steps below follow the PRIME/SPRAY valve replacement in Titan's Impact 640 service manual, which the Impact 440 manual repeats with the same kit, 700-258.

Signs the PrimeSpray Valve Is Leaking or Stuck

Symptoms that point to the valve

  • Material flows from the return hose with the valve in SPRAY. Titan's troubleshooting chart lists this under a pump that will not build or maintain pressure, and the fix it gives is to clean or replace the PRIME/SPRAY valve.
  • Pressure that falls away while the tip, filters and siphon connection all check out, and paint keeps returning to the bucket.
  • A blinking yellow pressure light in SPRAY at a high knob setting. The 440 manual reads that as a worn tip or a sprayer in need of service.
  • A leak at the valve itself. Titan's chart says to check all connections for external leaks and tighten them, after relieving pressure.

Check the return hose and handle first

Start with the handle. The operation section moves it down for PRIME and up for SPRAY, and the Impact 440 chart's first answer to a sprayer that will not prime is simply that the valve was left in SPRAY. If paint trickles from the return hose in SPRAY, make sure the handle is fully up. Because the chart's remedy is to clean or replace the valve, a thorough flush is the cheap first try: the cleanup steps run solvent through the unit and out the return hose in PRIME at the RAPID CLEAN setting. If the return persists after a clean flush, replace the valve.

PrimeSpray Valve Parts and Tools

Valve assembly, handle, bypass hose and seals

1
PrimeSpray Valve AssemblyCallout 31 on the Impact 440 fluid section page, and the replacement kit number Titan's procedure is written around.Part #700-258
2
Valve HandleCallout 32. Comes off once the groove pin is out.Part #700-697
3
Groove PinCallout 33. Passes through the handle and the valve stem to lock them together.Part #700-759
4
Cam BaseCallout 34. Sits over the valve housing, greased and lined up with the pump block.Part #700-252B
5
GasketCallout 38 on the fluid section page. The manual says the gasket must be in place before the new housing goes in; compare it with yours.Part #700-537
6
Bypass HoseCallout 36 on the Impact 440 main assembly page. Titan's valve procedure has no hose step, so replace it only if it is damaged.Part #702-239

Tools and supplies

  • The 700-258 PRIME/SPRAY valve replacement kit.
  • A wrench for the valve housing assembly.
  • Grease for the cam base.
  • Solvent (water for latex, mineral spirits for oil-based) and a metal waste container for the test.
  • Eye protection, which Titan says to wear whenever you service the sprayer.

Pressure Relief Before You Touch the Valve

This is the one job where the part you are replacing is also part of the relief routine. Titan's Pressure Relief Procedure ends by turning the PRIME/SPRAY valve down to PRIME, after the gun has been locked, the switch and knob turned OFF, the trigger lock released and the grounded gun triggered into a metal container to empty the hose. Hold the return hose in the waste container as you move the valve, in case the pump is still pressurized, then lock the gun and unplug the sprayer before the pin comes out. Our Impact pressure relief and injection safety basics cover each step.

Pressure stays after the motor stopsThe 440 manual warns that switching off the motor does not release pressure; only the PRIME/SPRAY valve or the gun does. Never point the gun at anyone, and if paint is injected through skin, get emergency medical help straight away.

Replacing the PrimeSpray Valve: Step by Step

Step 1: Relieve pressure and unplug

Carry out the full Pressure Relief Procedure so the valve finishes in PRIME, then pull the plug. Titan's valve procedure has no hose-removal step.

Step 2: Push out the groove pin

Push the groove pin out of the valve handle. It runs through the handle and the valve stem, so the handle is free once it is out.

Step 3: Remove the handle, cam base and valve assembly

Lift off the valve handle and the cam base. Put a wrench on the valve housing assembly, loosen it and unscrew it from the pump block.

Step 4: Fit the new valve and gasket

Check that the gasket is in place on the new valve housing assembly, thread it into the pump block and tighten it securely with the wrench.

Step 5: Grease and align the cam base

Set the cam base over the valve housing assembly, grease it, and turn it so its cam lines up with the pump block.

Step 6: Pin the handle back on

Fit the handle and line up the hole in the valve stem with the hole in the handle. Insert the groove pin through the handle and the stem so the handle is locked in position.

Step 7: Reconnect and prime

Plug the sprayer back in and prime it with solvent as the Operation section describes, then run the PRIME and SPRAY checks below before you load paint.

Grease, then alignTitan pairs two small details in step 5: the cam base gets grease, and its cam must line up with the pump block. Both come before the handle goes back on, because the groove pin then locks the handle to the stem.

Test the Impact 440 After Replacing the PrimeSpray Valve

Check the valve in PRIME and SPRAY

Siphon tube in solvent, return hose in the metal waste container, knob at MIN, handle down to PRIME, switch on: solvent should come back through the return hose. Switch off, lift the handle to SPRAY with no tip on the gun, switch on, release the trigger lock and trigger the grounded gun into the container until clean solvent flows. Lock the gun. With the valve in SPRAY, nothing should keep running out of the return hose, which was the original fault. The routine is the same one in our guide to priming an airless sprayer.

Look for leaks under pressure

Set the gun down, turn the knob slowly clockwise and check the valve housing and every connection for leaks. If anything weeps, run the pressure relief steps before tightening. On the 440, blinking yellow on the pressure indicator means little or no pressure (it is then safe to move the valve), and solid green means 1901 to 3300 PSI. The paint hose should stiffen as pressure builds. Titan's service notes say to test every repair before normal use and recheck the procedure if the problem remains.

Mistakes to Avoid When Replacing the Impact 440 PrimeSpray Valve

  • No gasket under the new housing. The manual's first check before threading it in is that the gasket is in place.
  • A dry or misaligned cam base. Grease it and line its cam up with the pump block before the handle goes on.
  • Forcing the pin. Line up the hole in the valve stem with the hole in the handle first; the pin has to pass through both.
  • Moving the valve with pressure on it. On the 440, move it when the indicator blinks yellow, and hold the return hose in the waste container when you switch to PRIME.
  • Tightening a weeping connection under pressure. Relieve pressure first, every time.
  • Replacing the valve for a tip problem. A worn or oversized tip also costs pressure; rule it out first.

Order the Impact 440 PrimeSpray Valve Parts

The valve group is callouts 31 to 38 on the Impact 440 fluid section diagram: the 700-258 PrimeSpray valve assembly, the 700-697 valve handle, the 700-759 groove pin and the cam base. The 702-239 bypass hose is on the Impact 440 main assembly page. Our Impact 440 parts guide shows where the valve sits among the other fluid section parts. If the valve was not the cause, see replacing the packings or the outlet valve, or browse all repair guides.

PRIME/SPRAY valve parts for the Impact 440:

Titan 700-258 PrimeSpray Valve Assembly −10%
Titan
Titan 700-258 PrimeSpray Valve Assembly
Part #: 700-258
(1)
$112.09 $125.10 Save $13.01
Buy Now
Titan 700-697 Valve Handle Genuine OEM
Titan
Titan 700-697 Valve Handle
Part #: 700-697
$18.50
Buy Now
Titan 700-759 Groove Pin Genuine OEM
Titan
Titan 700-759 Groove Pin
Part #: 700-759
$3.80
Buy Now
Titan 700-252B Cam Base Genuine OEM
Titan
Titan 700-252B Cam Base
Part #: 700-252B
$6.30
Buy Now
Titan 700-537 Gasket #1 Seller
Titan
Titan 700-537 Gasket
Part #: 700-537
$2.50
Buy Now
Titan 702-239 Bypass Hose −8%
Titan
Titan 702-239 Bypass Hose
Part #: 702-239
$48.42 $52.80 Save $4.38
Buy Now
 
Impact 440 Fluid Section Assembly

PrimeSpray valve, handle, groove pin, cam base, O-rings and gasket at callouts 31-38.

 
Impact 440 Main Assembly

Bypass hose, return tube fitting, siphon tube and the controls.

 
Impact 640 Fluid Section Assembly

The same PrimeSpray valve callouts for owners of the 640.

Checking a PrimeSpray Valve Part Number?

Tell us your Impact model and serial number and we will confirm the valve, handle, pin or gasket on your diagram before you order.

(713) 931-0006Order by Parts Diagram
Frequently Asked Questions
What does the PRIME/SPRAY valve do?
It sets the path for the paint. Down in PRIME, the pump circulates fluid back out of the return hose at little or no pressure, which is how you prime and flush the sprayer and how the pressure relief procedure bleeds the pump. Up in SPRAY, the fluid is sent to the hose and gun. On the Impact 440, a blinking yellow pressure light tells you it is safe to move the valve between positions.
Paint comes out of the return hose in SPRAY. Is the valve worn?
That is the exact symptom Titan's troubleshooting chart links to the PRIME/SPRAY valve, and its remedy is to clean or replace the valve. First make sure the handle is fully in SPRAY and give the sprayer a full flush. If paint still returns to the bucket in SPRAY, replace the valve housing assembly with the 700-258 kit, following the steps above.
Do I replace the bypass hose at the same time?
Titan's manual does not call for it. The PRIME/SPRAY valve procedure has no hose step at all and does not ask you to disconnect it. Replace the 702-239 bypass hose only if it is cracked, leaking or damaged; Titan's chart says to check every connection for external leaks and tighten as needed, after relieving pressure.
On this page