Please wait while we process your order...

Titan 700-252B Cam Base

$6.30
Available to Order
Part #: 700-252B

OEM Titan PRIME/SPRAY Valve Component

Titan 700-252B Cam Base is a genuine OEM component that supports the cam operated PRIME/SPRAY bypass valve mechanism, restoring smooth valve actuation and reliable mode selection in compatible airless sprayers.

Brand: Titan Part #: 700-252B Type: Cam Base Use: Bypass Valve Actuation

Compatibility Snapshot

Brand Compatible Models Part Number Serviced With
Titan Impact 740, Impact 1140, Impact 1040T, Helix A/B, MultiFinish 440, selected Impact 440/640/840, RentSpray Plus, RentSpray 700 700-252B Valve handle, groove pin, bypass valve, gasket, valve housing

Replacing a worn cam base eliminates valve binding and restores precise switching between PRIME and SPRAY modes.

Quantity
Buy Now
Genuine OEM Part Fast Shipping Easy Returns

Titan PRIME/SPRAY Valve Repair Part

Titan 700-252B Cam Base for Airless Sprayer Bypass Valve Service

Titan 700-252B is an OEM cam base that supports the cam operated PRIME/SPRAY bypass valve mechanism. This component provides the mounting and pivot point that converts handle rotation into precise valve movement, enabling reliable switching between priming and spraying modes.

OEM: Titan Part #: 700-252B Type: Cam Base Use: Bypass Valve Actuation
Detail Technical / Commercial Information
Product Overview OEM Titan cam base that provides the mounting and pivot point for the PRIME/SPRAY valve cam mechanism on compatible airless sprayers.
Function Provides a stable mounting surface and pivot point for the cam mechanism. Converts the rotary motion of the valve handle into precise movement to switch the valve between PRIME and SPRAY modes. Ensures proper alignment of the cam with its follower for accurate valve positioning. A worn or damaged cam base causes binding, sticking, or erratic valve operation.
Material / Specification Precision molded construction. Lubricate with grease during reassembly. Confirm exact specification against your model parts diagram before ordering.
Industrial Applications Professional sprayer repair, PRIME/SPRAY valve service, bypass valve rebuild, rental fleet servicing, and contractor equipment restoration.
Compatible Titan Machines Manufacturer manuals identify the part for Impact 1140, Impact 1040T, and Helix A/B. Additional catalog listings include MultiFinish 440 and selected Impact 440, 640, 740, and 840 configurations, plus RentSpray Plus and RentSpray 700. Verify your exact model revision against the applicable parts diagram before ordering.
OEM Part Number 700-252B Cam Base.
Related Parts Commonly Serviced Together Valve handle, groove pin, bypass valve, gasket, and valve housing assembly. Inspect all components during valve service.
Common Problems Solved Valve binding or sticking, erratic valve operation, difficulty switching between PRIME and SPRAY modes, worn or corroded mounting surfaces, and improper cam alignment.
Target Users / Markets Painting contractors, equipment rental fleets, maintenance departments, and repair shops servicing Titan airless sprayers.
OEM & Brand Information Genuine Titan OEM component designed for correct fitment in compatible sprayer valve systems.
Commercial Benefits Restores proper valve operation, prevents binding and erratic behavior, ensures reliable mode selection, and extends valve mechanism life.

When replacing the 700-252B cam base, shut down the sprayer, disconnect power, and follow the complete pressure relief procedure before opening the valve assembly. Inspect the valve handle, groove pin, gasket, and bypass valve mechanism for additional wear. Lubricate the cam base with grease during reassembly. Note that 700-252 and 700-252B are listed separately in Titan documentation for different machine configurations; do not substitute one for the other without confirming an authorized supersession for your exact model.

Frequently Asked Questions

Contractor focused answers for confirming fitment, function, and service value.

Common Questions
What is Titan 700-252B Cam Base used for?

It supports the cam actuation mechanism of the PRIME/SPRAY bypass valve, ensuring smooth movement and proper alignment of the valve controls.

Which Titan sprayers use 700-252B?

Manufacturer manuals identify it for Impact 1140, Impact 1040T, and Helix A/B. Catalog listings also include MultiFinish 440, selected Impact 440/640/740/840, RentSpray Plus, and RentSpray 700. Verify your exact model revision.

Are 700-252B and 700-252 interchangeable?

Their interchangeability has not been established. Titan manuals list both part numbers in different machine configurations. Order the exact part number specified for your sprayer.

Can a damaged cam base cause valve problems?

Yes. Damage or excessive wear can cause binding, sticking, or difficulty switching between PRIME and SPRAY modes. Similar symptoms may also come from the handle, pin, or bypass valve itself.

What parts should be inspected with the cam base?

Inspect the valve handle, groove pin, bypass valve, gasket, and surrounding mounting surfaces. Confirm part numbers using your model exploded diagram.

No reviews yet. Be the first to review this product!

Recently Viewed

Titan 2360658A Fitting Assembly (can be ordered as Titan 2429834) −5%
Titan
Titan 2360658A Fitting Assembly (can be ordered as Titan 2429834)
Part #: 2360658A
$28.73 $30.40 Save $1.67
Buy Now

Added to cart

Your Cart
No items in cart.
Add more items
Total 0
Checkout Modify Cart