Please wait while we process your order...

Product successfully added to your cart.
Placeholder Image

Quantity in Cart: 1


Continue Shopping Shopping Cart
Item removed from Cart
X
 
×
Titan 944-026 Valve Stem Stop

Titan 944-026 Valve Stem Stop

Sourced From:
Titan Tools Inc.

Part 944-026 is a replacement valve stem stop for a wide range of compatible spray equipment. This component limits the travel of a valve stem, ensuring proper valve opening and closing. When the original stop becomes worn, damaged, or lost, replacement restores correct valve operation.


Part Number 944-026
Part Description Valve stem Stop
Brand Universal
Fits PowrTwin 12000GHD; PowrTwin 12000GH; PowrTwin 12000 GHD; PowrTwin 8900GH; PowrTwin 6900GH; PowrTwin 4900GH; PowrTwin 4500; PowrTwin 3500; PowrTwin 3500 50th anniversary; PowrLiner 8900; PowrLiner 6000; PowrLiner 5000; PowrLiner 4900; PowrLiner 4000; Hydra M and Hydra Pro 2000_4000; Hydr M nad Hydra Pro Super; Commander; Admiral; 0528925N_2000_4000
Condition New
 

$26.1

Valve Stem Stop 944-026 for Multi-Brand Spray Equipment

The 944-026 valve stem stop is a direct replacement component for an extensive range of spray equipment including numerous PowrTwin models (12000GHD, 12000GH, 12000 GHD, 8900GH, 6900GH, 4900GH, 4500, 3500, 3500 50th anniversary), various PowrLiner models (8900, 6000, 5000, 4900, 4000), Hydra M and Hydra Pro 2000_4000, Hydr M nad Hydra Pro Super, Commander, Admiral, and 0528925N_2000_4000 equipment. This component is installed in a valve assembly to limit the travel of the valve stem. By providing a positive stop, it ensures that the valve opens only to the designed position and closes fully, preventing over-travel that could damage internal components or affect flow control. The stop may be an adjustable feature or a fixed component. A properly functioning valve stem stop is essential for accurate valve timing, consistent flow, and preventing internal damage. A worn, damaged, or missing stop can allow the stem to travel too far, causing improper sealing, reduced flow, or mechanical damage. This replacement stop is manufactured to exact specifications for size, shape, and material. Installation requires proper positioning within the valve assembly. Regular inspection during valve service helps identify stops that need replacement.

Service Guidance: If a valve operates erratically, fails to open or close fully, or shows signs of internal damage, inspect the valve stem stop. Replace if worn, damaged, or missing.

What it does and when to replace it

Function of the valve stem stop
Travel limitation Limits valve stem movement to proper range
Damage prevention Prevents over-travel and internal damage
Position control Ensures full open and closed positions
When replacement is needed
Worn stop Stop surface worn, allowing excess travel
Damaged / cracked Stop broken, no longer functions
Missing stop Stop lost, valve travel unrestricted
Valve malfunction Valve does not open or close fully

Compatibility

Valve stem stop 944-026 is compatible with the following models. Verify fit using your equipment's parts diagram.

Compatible Series Models (partial list)
PowrTwin 12000GHD, 12000GH, 12000 GHD, 8900GH, 6900GH, 4900GH, 4500, 3500, 3500 50th anniversary
PowrLiner 8900, 6000, 5000, 4900, 4000
Hydra Hydra M and Hydra Pro 2000_4000; Hydr M nad Hydra Pro Super
Commander / Admiral Commander; Admiral
Other 0528925N_2000_4000

Related parts commonly serviced together

When replacing the valve stem stop, inspect these associated components to ensure proper valve function.

Valve stem

Check for wear or damage.

Valve seat / seal

Inspect sealing surfaces.

Valve spring

Check for proper tension.

Frequently Asked Questions

It is a valve stem stop that limits the travel of a valve stem, ensuring proper opening and closing on compatible spray equipment.

It fits an extensive range of PowrTwin, PowrLiner, Hydra, Commander, Admiral, and 0528925N models as listed in the compatibility table.

Signs include worn stop surface, damage or cracks, missing stop, or valve failing to open/close fully.

Yes, without a stop, the stem can over-travel, causing internal damage, improper sealing, and valve failure.