Titan 0138284A BellyPan / Fan Assembly

Titan 0138284A BellyPan / Fan Assembly

Sourced From:
Titan Tools Inc.

Part number 0138284A is a BellyPan / Fan Assembly that provides cooling air distribution and protective enclosure for compatible Helix plural component spray systems. This integrated assembly houses the cooling fan and directs airflow across critical electronic and hydraulic components to maintain optimal operating temperatures.

Part Number 0138284A
Part Description BellyPan / Fan Assembly
Fits Helix FR
Condition New

Retail Price: $466.93
You save: $68.17 (14.60%)
Our Price: $398.76

BellyPan / Fan Assembly for Helix FR Plural Component Systems

Part number 0138284A is a BellyPan / Fan Assembly, an integrated cooling and protective enclosure specifically engineered for the Titan Helix FR plural component spray system. This assembly mounts to the lower chassis of the proportioner and serves two critical functions: it houses the electric cooling fan that draws ambient air through the electronic control enclosure, and it forms the protective belly pan that shields sensitive hydraulic and electrical components from debris, overspray, and impact damage during transport and operation. The Helix FR is designed for high-volume application of polyurea, polyurethane, and epoxy coatings requiring precise temperature control and ratio accuracy, making reliable cooling essential for continuous duty cycles.

The integrated fan assembly is a vital component of the Helix FR thermal management system. Plural component proportioners generate significant heat during operation from the hydraulic pump, electric motors, and the SureFire™ heating system that maintains coating temperatures up to 190°F. The belly pan fan actively draws cooling air across the control panel electronics, pressure transducers, and hydraulic components, preventing thermal overload and ensuring consistent performance during extended spraying applications. The fan operates automatically when the system is powered, providing continuous airflow protection. The belly pan structure itself is fabricated from heavy-gauge formed steel with a corrosion-resistant finish, featuring precision-formed mounting points and airflow channels.

The BellyPan / Fan Assembly is subjected to continuous vibration, thermal cycling, and environmental exposure. Failure modes include fan motor bearing wear causing noise or failure, fan blade damage or imbalance, cracked or deformed belly pan structure from impact, corrosion of mounting hardware, and obstruction of airflow passages by accumulated debris. A failed fan motor or obstructed airflow can lead to overheating of electronic components, resulting in erratic system behavior, nuisance shutdowns, or permanent damage to the control system. Replacement with genuine 0138284A BellyPan / Fan Assembly restores proper cooling capacity and ensures reliable operation of the Helix FR system in demanding plural component applications.

Service Guidance: Regularly inspect the fan for proper operation and listen for unusual noise indicating bearing wear. Keep the belly pan and fan intake area free of debris and overspray accumulation. Verify that all mounting hardware is secure. Replace immediately if fan fails, makes excessive noise, or if belly pan is cracked or deformed.

What it does and when to replace it

What the belly pan/fan assembly does
Component Cooling Forces airflow across electronics and hydraulic components to prevent overheating
Protective Enclosure Shields sensitive system components from debris, overspray, and impact damage
Thermal Management Essential for continuous-duty plural component application cycles
When replacement is recommended
Fan Motor Failure Fan does not operate, operates intermittently, or makes excessive noise
Fan Blade Damage Blades are cracked, broken, or unbalanced causing vibration
Structural Damage Belly pan is cracked, bent, or has broken mounting tabs
Corrosion Severe rust or chemical degradation has compromised structural integrity

Compatibility

Part number 0138284A is specifically designed for the Titan Helix FR plural component spray system. This professional proportioner utilizes an integrated thermal management system requiring this dedicated BellyPan / Fan Assembly for proper cooling and component protection. The Helix FR features the SureFire™ heating system, electronic pressure control, and is designed for high-volume application of polyurea, polyurethane, and epoxy coatings. This assembly is a model-specific component engineered for the mounting configuration, airflow requirements, and dimensional specifications of this particular sprayer system. Always confirm fitment using the correct parts diagram for your exact model and serial number.

Compatible Models Component
Helix FR BellyPan / Fan Assembly

Related parts commonly serviced together

The BellyPan / Fan Assembly is part of the Helix FR thermal management system. When servicing this component, these related parts are often inspected or replaced at the same time.

Control Panel Assembly

The primary beneficiary of the cooling airflow. Inspect for dust accumulation and ensure ventilation ports are clear.

Hydraulic Pump Assembly

Located above the belly pan. Verify proper cooling airflow around pump housing.

Mounting Hardware Kit

Screws, nuts, and washers securing the belly pan to the chassis. Replace if corroded or damaged.

Frequently Asked Questions

It is a BellyPan / Fan Assembly that houses the cooling fan and provides protective enclosure for electronic and hydraulic components on the Titan Helix FR plural component spray system.

The Helix FR generates significant heat during operation from the hydraulic pump, electric motors, and the SureFire™ heating system which maintains coating temperatures up to 190°F. The cooling fan forces ambient air across the control panel electronics, pressure transducers, and hydraulic components to prevent thermal overload, ensure consistent performance, and protect sensitive electronic components from heat damage during extended spraying applications.

Signs of fan motor failure include: the fan does not operate when the system is powered, the fan operates intermittently or at reduced speed, unusual grinding or squealing noises indicating bearing wear, excessive vibration from an imbalanced fan blade, or visible damage to the fan blade assembly. If the fan fails, the system may overheat and experience erratic behavior or thermal shutdown.

This BellyPan / Fan Assembly is specifically designed for the Titan Helix FR plural component spray system. Always verify compatibility with your specific unit's parts diagram and serial number before ordering.