Titan/Wagner 0295451 Relay

Titan/Wagner 0295451 Relay

Sourced From:
Titan Tools Inc.

Part number 0295451 is a Relay that controls electrical power distribution to key components across a wide range of Advantage, PowrLiner, RentSpray, and SprayTech airless sprayer systems. This electromechanical switch ensures reliable operation of motors, pumps, and control circuits.

Part Number 0295451
Part Description Relay
Fits Advantage GPX 85; PowrLiner 2850 GB_D_F; PowrLiner 1800M, 2800M; RentSpray 400; SprayTech Airless Advantage EPX2155; SprayTech Airless EP2105; SprayTech Airless EPX2155; SprayTech GPX 85
Condition New

Retail Price: $152.7
You save: $19.09 (12.50%)
Our Price: $133.61

Relay for Advantage, PowrLiner, RentSpray, and SprayTech Sprayer Systems

Part number 0295451 is a Relay specifically engineered for use across a comprehensive range of professional sprayer systems including the Advantage GPX 85, PowrLiner 2850 GB_D_F line striper, PowrLiner 1800M and 2800M stripers, RentSpray 400 rental sprayer, and multiple SprayTech models including Airless Advantage EPX2155, Airless EP2105, Airless EPX2155, and GPX 85. This electromechanical switching device controls the distribution of electrical power to critical components such as motors, pumps, and control circuits. When energized by a low-power signal from the control board or pressure switch, the relay closes its internal contacts, allowing high-current power to flow to the motor or other loads. This function is essential for safe and reliable equipment operation.

The relay is typically mounted within the control panel or electrical enclosure of the sprayer, often in close proximity to the circuit board and other control components. Service documentation for these models indicates that the relay can be tested by applying 12 VDC across the coil terminals and listening for an audible click as the contacts close. If the relay fails to click, or if the motor does not run when the relay is energized and proper input voltage is verified, the relay is likely faulty and requires replacement. The relay is manufactured to exact specifications for coil voltage, contact current rating, and mounting configuration to ensure proper fit and function across these diverse platforms.

Relays are subjected to continuous electrical and mechanical stress during operation. Failure modes include welded contacts causing continuous motor operation, burned or pitted contacts causing intermittent power, coil burnout preventing relay activation, and mechanical fatigue of internal components. A failed relay can cause the motor not to run, run continuously without stopping, or operate erratically. Replacement with genuine 0295451 relay restores proper electrical control and ensures reliable operation of Advantage, PowrLiner, RentSpray, and SprayTech sprayer systems.

Service Guidance: Before testing or replacing the relay, always unplug the sprayer and perform pressure relief procedure. Test relay by applying 12 VDC to coil terminals; an audible click indicates proper mechanical operation. Verify input voltage to the coil and continuity across contacts. Replace immediately if relay fails to click or contacts are burned.

What it does and when to replace it

What the relay does
Power Switching Controls high-current power to motor and components using low-power signals
Circuit Protection Isolates control circuits from high-current loads for safety
System Control Enables automatic operation based on pressure switch or control board signals
When replacement is recommended
Motor Won't Run No motor operation with proper input voltage and coil signal
Continuous Operation Motor runs constantly and won't shut off
No Audible Click Relay fails to click when coil voltage is applied
Burned Contacts Visual inspection shows pitted or welded contacts

Compatibility

Part number 0295451 is specifically designed for a comprehensive range of professional sprayer systems including Advantage GPX 85; PowrLiner 2850 GB_D_F; PowrLiner 1800M and 2800M; RentSpray 400; SprayTech Airless Advantage EPX2155; SprayTech Airless EP2105; SprayTech Airless EPX2155; and SprayTech GPX 85. The PowrLiner models are professional line striping systems for parking lots and roadways. The GPX and EPX series are lightweight, professional airless sprayers for residential and commercial applications. The RentSpray 400 is designed for the rental market. These units share common electrical control architecture requiring this specific relay. This relay is a model-specific component engineered for the voltage requirements, current ratings, and mounting configurations of these particular sprayer systems. Always confirm fitment using the correct parts diagram for your exact model and serial number.

Compatible Models Component
Advantage GPX 85 Relay
PowrLiner 2850 GB_D_F
PowrLiner 1800M, 2800M
RentSpray 400
SprayTech Airless Advantage EPX2155
SprayTech Airless EP2105
SprayTech Airless EPX2155
SprayTech GPX 85

Related parts commonly serviced together

The relay is part of the electrical control system. When servicing this component, these related parts are often inspected or replaced at the same time.

Circuit Board

The control board that sends the signal to energize the relay. Inspect for damage or loose connections.

Pressure Switch

Controls relay operation based on system pressure. Test for proper function.

Wiring Harness

Electrical connections to the relay. Inspect for damage, corrosion, or loose terminals.

Frequently Asked Questions

It is a Relay that controls electrical power distribution to motors and components across Advantage GPX 85, PowrLiner 2850 GB_D_F, PowrLiner 1800M/2800M, RentSpray 400, and multiple SprayTech airless sprayer models including EP2105, EPX2155, and GPX 85.

Apply 12 VDC across the coil terminals. An audible click indicates the relay is mechanically functioning. With the coil energized, test continuity across the switch contacts; they should show low resistance. When de-energized, the contacts should show infinite resistance. If the relay fails to click or contacts show incorrect continuity, replacement is required.

Common symptoms include the motor not running when the sprayer is turned on, the motor running continuously and not shutting off, intermittent motor operation, and no audible click from the relay when power is applied. A failed relay can also cause erratic pressure control or complete loss of power to the motor.

This relay is compatible with Advantage GPX 85; PowrLiner 2850 GB_D_F; PowrLiner 1800M, 2800M; RentSpray 400; SprayTech Airless Advantage EPX2155, EP2105, EPX2155, and GPX 85. These professional units share common electrical control architecture. Consult your specific unit's parts diagram.