Please wait while we process your order...

Product successfully added to your cart.
Placeholder Image

Quantity in Cart: 1


Continue Shopping Shopping Cart
Item removed from Cart
X
 
×
Titan 441-206 Adaptor O-ring

Titan 441-206 Adaptor O-ring

Sourced From:
Titan Tools Inc.

Part number 441-206 is an Adaptor O-ring that provides a leak-proof seal between fluid system components on compatible Hydra M and Hydra Pro sprayer systems. This precision elastomeric seal prevents fluid leakage and maintains system pressure for reliable equipment operation.

Part Number 441-206
Part Description Adaptor O-ring
Fits 0528925N_2000_4000; Hydr M nad Hydra Pro Super; Hydra M and Hydra Pro 2000_4000
Condition New

Retail Price: $45.1
You save: $2.48 (5.50%)
Our Price: $42.62

Adaptor O-ring for Hydra M and Hydra Pro Spray Systems

Part number 441-206 is a precision-engineered Adaptor O-ring specifically designed for use with 0528925N_2000_4000, Hydra M and Hydra Pro Super, and Hydra M and Hydra Pro 2000_4000 series spray systems. These professional units include the Hydra M line of electric airless sprayers and the Hydra Pro series, both engineered for high-volume commercial and industrial coating applications delivering up to 4000 PSI operating pressure. This O-ring is installed at the interface between fluid system adaptors and components, creating a leak-proof seal that prevents material leakage and maintains system pressure. The elastomeric material is specifically formulated to resist the chemical attack of solvents, water-based coatings, and abrasive pigments encountered in professional finishing environments.

The Adaptor O-ring is a critical sealing component in multiple locations throughout the fluid system, including connections between hoses, fittings, pumps, and guns. Its precise dimensions ensure proper compression when the adaptor is tightened, creating a positive seal that withstands continuous pressure cycling and vibration. The O-ring material maintains its flexibility and sealing properties over time, compensating for minor surface irregularities in the mating components. Regular inspection and timely replacement of this O-ring is essential for preventing leaks and ensuring reliable equipment performance.

O-rings are subjected to continuous compression, thermal cycling, and chemical exposure. Failure modes include hardening or cracking from age and heat, compression set causing loss of sealing force, extrusion from high pressure, and physical damage during installation. A worn or damaged O-ring will allow fluid to leak past the seal, causing pressure loss, material waste, and potential component damage. Replacement with genuine 441-206 Adaptor O-ring restores proper sealing integrity and ensures reliable operation of Hydra M and Hydra Pro spray systems.

Service Guidance: When replacing O-rings, ensure the sealing groove is clean and free of debris. Lubricate the new O-ring with an appropriate grease or light oil to prevent rolling and pinching during installation. Do not overtighten fittings, as this can damage the O-ring or mating surfaces. Replace O-rings whenever components are disassembled for service.

What it does and when to replace it

What the adaptor O-ring does
Fluid Containment Seals connections between fluid system components
Pressure Maintenance Prevents leakage under high operating pressure
Contamination Barrier Blocks external debris from entering fluid path
When replacement is recommended
Visible Leakage Fluid seeping from adaptor connection during operation
O-ring Degradation Seal is flattened, cracked, hardened, or has pieces missing
Component Disassembly Whenever an adaptor is removed for service
Preventive Maintenance Replace during annual service or major system overhaul

Compatibility

Part number 441-206 is specifically designed for use with 0528925N_2000_4000, Hydra M and Hydra Pro Super, and Hydra M and Hydra Pro 2000_4000 series spray systems. These professional units include the Hydra M line of electric airless sprayers and the Hydra Pro series, both engineered for high-volume commercial and industrial coating applications delivering up to 4000 PSI operating pressure. This Adaptor O-ring is a universal component engineered for the sealing requirements across these diverse professional platforms. Always confirm fitment using the correct parts diagram for your exact model and serial number.

Compatible Models Component
0528925N_2000_4000 Adaptor O-ring
Hydr M nad Hydra Pro Super
Hydra M and Hydra Pro 2000_4000

Related parts commonly serviced together

The Adaptor O-ring is typically replaced during service of the adaptor or fitting it seals. When servicing, these related parts are often addressed at the same time.

Fluid Adaptor

The fitting that the O-ring seals. Inspect for thread damage or wear on sealing surfaces.

Seal Lubricant

Light oil or silicone grease recommended for O-ring installation to prevent rolling and ensure proper seating.

Mating Component

The part that the adaptor connects to. Inspect for burrs, scratches, or corrosion.

Frequently Asked Questions

It is an Adaptor O-ring that provides a leak-proof seal between fluid system components on 0528925N_2000_4000, Hydra M and Hydra Pro Super, and Hydra M and Hydra Pro 2000_4000 series spray systems.

Signs include visible fluid leakage at the adaptor connection, difficulty maintaining system pressure, and during disassembly, O-rings that are flattened, cracked, hardened, or have pieces missing require replacement. As a general rule, O-rings should be replaced whenever a sealed connection is opened for service.

Yes. Applying a light film of appropriate lubricant such as silicone grease or light oil to the O-ring before installation is recommended. Lubrication helps the O-ring seat properly during assembly, prevents rolling and pinching, and extends seal life. Do not use petroleum-based greases that can degrade the elastomer.

This O-ring is compatible with 0528925N_2000_4000, Hydra M and Hydra Pro Super, and Hydra M and Hydra Pro 2000_4000 series spray systems. These professional units deliver up to 4000 PSI for commercial and industrial coating applications. Consult your specific unit's parts diagram.