Titan 0509762A Inlet Screen (replaces Titan 103-627)

Titan 0509762A Inlet Screen (replaces Titan 103-627)

Sourced From:
Titan Tools Inc.

PowrTwin part 0509762A is an Inlet Screen that replaces Titan 103-627 and is used to filter debris from material before it enters the pump. When the screen becomes clogged or damaged, flow restriction increases and pump cavitation may occur. This replacement screen restores proper inlet filtration and flow on compatible PowrTwin, PowrLiner, and Hydra units.

Part Number 0509762A
Part Description Inlet Screen (replaces Titan 103-627)
Brand PowrTwin
Fits PowrTwin 12000 Plus DI service, PowrTwin 12000 Plus DI Operation, PowrTwin 6900 , 12000 Plus DI, PowrTwin 4900 , 6900 , 8900, 12000 Plus, PowrLiner 6950_1, PowrLiner 6950, PowrLiner 4950, PowrLiner 4955, 6955, 8955, Hydra M and Hydra Pro 2000_4000, Hydr M and Hydra Pro Super, 0528925N_2000_4000
Condition New

Retail Price: $46.3
You save: $3.52 (7.60%)
Our Price: $42.78

 

Inlet Screen for PowrTwin, PowrLiner, and Hydra Series Equipment

The PowrTwin 0509762A Inlet Screen is a replacement filtration component that directly replaces Titan part 103-627, designed to strain debris and contaminants from coating material before it enters the pump inlet. On compatible equipment including the PowrTwin 12000 Plus DI service, 12000 Plus DI Operation, 6900 and 12000 Plus DI, 4900, 6900, 8900, and 12000 Plus, as well as PowrLiner 6950_1, 6950, 4950, 4955, 6955, 8955, Hydra M and Hydra Pro 2000_4000, Hydr M and Hydra Pro Super, and model 0528925N_2000_4000, this inlet screen provides the first line of defense against large particles that could damage the pump's internal components. A clogged screen restricts material flow, causing the pump to struggle, cavitate, or lose prime. A torn or damaged screen allows debris to enter the pump, potentially causing scoring of cylinders, piston wear, or valve damage. Over time, screens accumulate dried material, fibers, and other debris that reduce flow area. Replacing a worn or clogged inlet screen restores proper flow, protects the pump from abrasive damage, and ensures consistent spray performance. This genuine PowrTwin replacement screen meets original equipment specifications for mesh size, material compatibility, and dimensional accuracy. When installing a new inlet screen, inspect the screen housing for damage, ensure the screen seats properly, and verify that no debris bypasses the screen during installation. Users should always verify compatibility with their specific model and revision before installation. Regular inlet screen inspection and cleaning should be part of preventive maintenance programs, with replacement recommended when screens show damage or cannot be fully cleared of debris.

Service Guidance: If the equipment exhibits pump cavitation, loss of prime, reduced flow, or difficulty priming, inspect the inlet screen for clogging or damage before returning the unit to service.

What it does and when to replace it

What the Inlet Screen does
Debris filtration Strains large particles before they enter the pump
Pump protection Prevents scoring, wear, and damage to internal components
  Flow maintenance Allows proper material flow when clean and unclogged
When replacement is recommended
Clogged screen Visible debris buildup restricting flow
Screen damage Tears, holes, or bent frame compromising filtration
Pump cavitation Pump struggles, makes knocking sounds, or loses prime
Reduced output Lower flow rate with no other restrictions found

Compatibility

PowrTwin part 0509762A is compatible with the following equipment. Always confirm fitment using the correct parts diagram for your exact model and revision.

Compatible Models Component
PowrTwin 12000 Plus DI service, 12000 Plus DI Operation, 6900, 12000 Plus DI, 4900, 6900, 8900, 12000 Plus Inlet Screen
PowrLiner 6950_1, 6950, 4950, 4955, 6955, 8955 Inlet Screen
Hydra M and Hydra Pro 2000_4000, Hydr M and Hydra Pro Super, 0528925N_2000_4000 Inlet Screen

Related parts commonly serviced together

Inlet flow problems are often caused by more than one component. When servicing the inlet screen, these parts are commonly inspected at the same time.

Suction hose and fittings

Collapsed or clogged suction hoses restrict flow regardless of screen condition.

Inlet housing and seal

Damaged housings or missing seals allow air ingestion and loss of prime.

Pump inlet valve

A stuck or worn inlet valve can cause cavitation and priming issues.

Frequently Asked Questions

It is an Inlet Screen that replaces Titan 103-627, used to filter debris from material before it enters the pump on compatible PowrTwin, PowrLiner, and Hydra equipment.

Common signs include visible debris clogging the screen, tears or holes in the screen material, pump cavitation or knocking sounds, loss of prime, or reduced flow with no other restrictions found.

PowrTwin 12000 Plus DI service, 12000 Plus DI Operation, 6900, 12000 Plus DI, 4900, 6900, 8900, 12000 Plus; PowrLiner 6950_1, 6950, 4950, 4955, 6955, 8955; Hydra M and Hydra Pro 2000_4000, Hydr M and Hydra Pro Super, 0528925N_2000_4000.

Cleaning with compatible solvent may extend life if the screen is undamaged. Replace if the screen shows tears, bent frame, or if cleaning does not restore full flow.