Please wait while we process your order...

Product successfully added to your cart.
Placeholder Image

Quantity in Cart: 1


Continue Shopping Shopping Cart
Item removed from Cart
X
 
×
📢 From June 8th to 25th, phone support will be limited. For assistance, please email us and we will respond as promptly as possible. Orders will continue to be processed normally.

CapSpray 55 Upper Housing Assembly Parts

CapSpray 55 Upper Housing Assembly Parts
Titan 0524537 Tool box door
Titan 0524537 Tool box door

Item No: 1

Part #: 0524537

Part number 0524537 is a Tool Box Door that provides secure access to the storage compartment on com...

$15.10
QTY:
Titan 0524538 Tool Box
Titan 0524538 Tool Box

Item No: 2

Part #: 0524538

Part number 0524538 is a Tool Box that provides integrated storage for accessories and tools on comp...

$15.30
QTY:
Titan 0524557 Top handle
Titan 0524557 Top handle

Item No: 3

Part #: 0524557

Part number 0524557 is a top handle designed for comfortable carrying and maneuvering of compati...

$6.90
QTY:
Titan 0524531A Upper Housing
Titan 0524531A Upper Housing

Item No: 4

Part #: 0524531A

Part number 0524531A is an upper housing that encloses and protects internal components of compa...

Retail Price: $190.00
You save: $23.75 (12.50%)
Our Price: $166.25
QTY:
Titan 0524558 Lower handle
Titan 0524558 Lower handle

Item No: 5

Part #: 0524558

Part number 0524558 is a lower handle designed for comfortable gripping and maneuvering of compa...

$6.90
QTY:
Titan 9802266 Motor Controller Screw
Titan 9802266 Motor Controller Screw

Item No: 6

Part #: 9802266

Part number 9802266 is a motor controller screw used to secure the motor controller or related e...

$2.50
QTY:
Titan 0524963  Lock Washer
Titan 0524963 Lock Washer

Item No: 7

Part #: 0524963

Part number 0524963 is a lock washer used to prevent fasteners from loosening due to vibration i...

$2.00
QTY:
Titan 0524553 CapSpray On/Off Switch
Titan 0524553 CapSpray On/Off Switch

Item No: 8

Part #: 0524553

Part number 0524553 is an on/off switch used to control electrical power to CapSpray and compati...

$24.50
QTY:
Titan 9803104 Screw
Titan 9803104 Screw

Item No: 12

Part #: 9803104

Part number 9803104 is a screw component designed for assembly and mounting applications on compatib...

$3.40
QTY:
Titan 0524536 Cup Holder (HVLP)
Titan 0524536 Cup Holder (HVLP)

Item No: 13

Part #: 0524536

Part number 0524536 is a Cup Holder specifically designed for HVLP spray gun systems, providing a co...

Retail Price: $69.00
You save: $5.73 (8.30%)
Our Price: $63.27
QTY:
Titan 9802265 Screw
Titan 9802265 Screw

Item No: 14

Part #: 9802265

Part number 9802265 is a screw used to fasten components securely in compatible sprayer systems....

$2.00
QTY:
Titan 0524566 Cable Clamp
Titan 0524566 Cable Clamp

Item No: 15

Part #: 0524566

Part number 0524566 is a cable clamp used to secure and organize electrical wiring or control ca...

$2.60
QTY:
Titan 9805287 Ground Screw
Titan 9805287 Ground Screw

Item No: 16

Part #: 9805287

Part number 9805287 is a ground screw used to establish a secure electrical ground connection in...

$2.50
QTY:
Titan 9822106 Lock washer #8 Ext Tooth Zinc
Titan 9822106 Lock washer #8 Ext Tooth Zinc

Item No: 17

Part #: 9822106

Part number 9822106 is a #8 External Tooth Lock Washer with zinc plating that provides vibration-res...

$2.50
QTY:

Buy Online CapSpray 55 Upper Housing Assembly Parts

The CapSpray 55 upper housing assembly includes components such as the 0524531A upper housing, 0524557 top handle, 0524553 on/off switch, 0524549 circuit breaker switch kit, 0524547 warning light assembly, and related fasteners, cable clamps, and hardware.

Together, these parts ensure safe operation, stable airflow management, and reliable handling during transport and spraying applications.

Housing Protection & Cooling Performance

Designed for professional HVLP finishing applications, the CapSpray 55 housing system helps protect the turbine assembly from dust, overspray, and physical damage while keeping electrical components secure and properly ventilated.

Replacing worn or damaged housing components helps maintain cooling efficiency, operator safety, and overall sprayer reliability.

Frequently Asked Questions

Overheating can occur if airflow through the upper housing becomes restricted due to clogged vents, damaged housing components, or loose internal airflow tubing. Inspect the housing and airflow passages regularly.

A faulty or worn 0524553 on/off switch may fail due to internal electrical wear, overspray contamination, or loose wiring connections inside the housing assembly.

Frequent breaker trips may indicate restricted turbine airflow, overloaded electrical supply, motor strain, or a failing 0524549 circuit breaker switch kit. Always verify proper voltage supply and airflow ventilation.

A damaged housing can reduce cooling efficiency, expose internal electrical components to dust and moisture, and increase vibration or noise during operation. Replacing cracked housing parts helps maintain turbine protection and airflow control.

The 0524547 warning light assembly may fail due to loose wiring, bulb failure, or electrical issues within the upper housing assembly. Inspect connectors and internal wiring before replacement.