Please wait while we process your order...

Titan 945-003 Copper Gasket

$4.70
Available to Order
Part #: 945-003

OEM Titan Sealing Component

Titan 945-003 Copper Gasket is an OEM sealing component that creates a leak-proof seal in high-pressure fluid connections within the 944/945 series bleed valve assembly on compatible Admiral, PowrTwin, PowrLiner, Hydra M, Hydra Pro, PowrCoat, and Commander spray systems.

Brand: Titan Part #: 945-003 Type: Copper Gasket System: Bleed Valve

Compatibility Overview

Brand Compatible Series Part Number Function
Titan Admiral, PowrTwin, PowrLiner, Hydra, PowrCoat, Commander 945-003 High-pressure bleed valve sealing

Copper construction deforms under compression to fill minor surface imperfections while withstanding high system pressures without extruding. A crushed, work-hardened, or damaged gasket causes fluid leaks at the bleed valve connection and loss of system pressure. Copper gaskets are single-use and should always be replaced during bleed valve service.

Quantity
Buy Now
Genuine OEM Part Fast Shipping Easy Returns

Titan Bleed Valve Gasket Replacement

Titan 945-003 Copper Gasket for Bleed Valve Assembly Service

Titan 945-003 is an OEM copper gasket designed for the 944/945 series bleed valve assembly on compatible Admiral, PowrTwin, PowrLiner, Hydra M, Hydra Pro, PowrCoat, and Commander spray systems. Listed as item 6 "Gasket, copper" in the official Titan parts breakdown for the 944-620 Bleed Valve Assembly, this precision sealing component creates a leak-proof seal in high-pressure fluid connections. The gasket seals the connection between the valve body and the valve seat, preventing fluid from escaping during pressure relief operations. Copper is an ideal gasket material because it is soft enough to deform under compression, filling minor imperfections in sealing surfaces, yet strong enough to withstand high system pressures without extruding or failing. Over time, copper gaskets may become work-hardened, crushed beyond their limit, or damaged during disassembly, leading to leaks. Copper gaskets are typically single-use and should not be reused. Always replace the copper gasket when servicing the bleed valve assembly, inspect sealing surfaces for damage, and ensure proper torque on the mating fastener.

OEM: Titan Part #: 945-003 Type: Copper Gasket System: Bleed Valve
Detail Technical / Commercial Information
Product Overview OEM Titan copper gasket that provides a leak-proof seal in high-pressure fluid connections within the 944/945 series bleed valve assembly.
Function Seals the connection between the valve body and the valve seat. Copper is soft enough to deform under compression, filling minor imperfections in sealing surfaces, yet strong enough to withstand high system pressures without extruding or failing.
System Location Bleed valve assembly, item 6. Listed in official Titan parts breakdowns for the 944-620 Bleed Valve Assembly.
Documented Compatible Models Admiral 944-620 Bleed Valve Assembly; Hydra M2000, M4000; Hydra Pro Super; PowrTwin 12000GHD, 12000GH, 8900GH, 6900GH, 4900GH, 4500, 3500; PowrLiner 8900, 6000, 5000, 4900, 4000; PowrCoat 730, 745, 940, 960, 975; Commander. Verify your exact model against the parts diagram.
OEM Part Number 945-003 Copper Gasket.
Common Problems Solved Visible fluid leaks at the bleed valve connection, loss of system pressure, and contamination of the fluid stream caused by a crushed, work-hardened, or damaged copper gasket.
Replacement Indicators Fluid leaks at the bleed valve connection, gasket shows signs of excessive crushing, work-hardening, or visible damage. Copper gaskets are single-use and should not be reused.
Related Parts Commonly Serviced Together Valve body (944-020), O-ring (944-004), valve stem stop (944-026), tungsten carbide ball (761-715), tungsten valve seat (944-904), knob assembly (944-024).
Installation Notes Always replace the copper gasket when servicing the bleed valve assembly. Inspect sealing surfaces for damage and ensure proper torque on the mating fastener.

The 945-003 Copper Gasket is a critical sealing component in the bleed valve assembly. If you notice fluid leaks at the bleed valve connection or if the gasket shows signs of crushing or damage, replace it with this genuine part. Copper gaskets are single-use and should always be replaced during bleed valve service. Verify model compatibility against your Titan service manual, as bleed valve configurations vary across sprayer platforms.

Frequently Asked Questions

Contractor-focused answers for confirming fitment and service value.

Common Questions
What is the Titan 945-003 Copper Gasket used for?

It creates a leak-proof seal between the valve body and valve seat in the bleed valve assembly, preventing fluid leaks and maintaining system pressure.

Which Titan sprayers use part 945-003?

It is documented for Admiral 944-620, Hydra M2000/M4000, Hydra Pro Super, PowrTwin 12000GH through 3500 series, PowrLiner 8900 through 4000 series, PowrCoat 730 through 975, and Commander. Always verify your exact model against the parts diagram.

Why use a copper gasket instead of other materials?

Copper is soft enough to deform under compression and fill minor sealing surface imperfections, yet strong enough to withstand high system pressures without extruding. It also resists corrosion.

Can the copper gasket be reused?

No. Copper gaskets are single-use and should not be reused. Always replace the gasket when servicing the bleed valve assembly.

What related parts should be inspected when replacing the gasket?

Inspect the valve body, PTFE O-ring (944-004), valve stem stop (944-026), tungsten carbide ball, and valve seat. Replace any worn components during the service.

No reviews yet. Be the first to review this product!

Recently Viewed

−16%
Titan
Titan 604-125 Hose Assembly
Part #: 604-125
$485.86 $578.40 Save $92.54
Buy Now
Titan 0090560 Return Tube Assembly −8%
Titan
Titan 0090560 Return Tube Assembly
Part #: 0090560
$38.62 $41.80 Save $3.18
Buy Now

Added to cart

Your Cart
No items in cart.
Add more items
Total 0
Checkout Modify Cart