Please wait while we process your order...

Product successfully added to your cart.
Placeholder Image

Quantity in Cart: 1


Continue Shopping Shopping Cart
Item removed from Cart
X
 
×
Titan 944-904 Tungsten Valve Seat

Titan 944-904 Tungsten Valve Seat

Sourced From:
Titan Tools Inc.

 

OEM Titan Valve Component

Titan 944-904 Tungsten Valve Seat is an OEM tungsten carbide component that provides a durable sealing surface for the check ball in the bleed valve assembly on compatible Admiral, PowrTwin, PowrLiner, Hydra M, and Hydra Pro spray systems.

Brand: Titan Part #: 944-904 Type: Tungsten Valve Seat Material: Tungsten Carbide

Compatibility Table

Brand Compatible Model Part Number Technical / Commercial Detail
Titan Admiral 944-620 Bleed Valve Assembly 944-904 Item 7 in 944-620 Bleed Valve Assembly.
Titan Hydra M2000, M4000; Hydra Pro Super 944-904 Used in 944-620 bleed valve assembly.
Titan PowrTwin, PowrLiner, PowrCoat, Commander 944-904 Wide compatibility across numerous Titan models.

Precision tungsten carbide valve seat restores proper sealing, prevents backflow, and extends bleed valve service life in high-wear applications.

Retail Price: $136.9
You save: $14.24 (10.40%)
Our Price: $122.66

Titan Valve Component Replacement

Titan 944-904 Tungsten Valve Seat for Bleed Valve Assembly

Titan 944-904 is an OEM tungsten carbide valve seat designed for the 944/945 series bleed valve assembly on compatible Admiral, PowrTwin, PowrLiner, Hydra M, and Hydra Pro spray systems. This precision component provides an exceptionally durable sealing surface for the check ball, ensuring reliable pressure relief and preventing backflow.

OEM: Titan Part #: 944-904 Type: Tungsten Valve Seat Material: Tungsten Carbide
Detail Technical / Commercial Information
Product Overview OEM Titan tungsten carbide valve seat that provides a durable sealing surface for the check ball in the bleed valve assembly.
Function Provides the sealing surface against which the tungsten carbide check ball seats during operation. Tungsten carbide is one of the hardest materials used in valve applications, offering exceptional resistance to abrasion, corrosion, and deformation. A smooth, perfectly round, and extremely hard seat is essential for achieving a positive seal and reliable valve operation in demanding environments.
Industrial Applications Professional sprayer repair, bleed valve maintenance, pressure relief system service, and rental fleet equipment servicing.
Compatible Titan Models Admiral 944-620 Bleed Valve Assembly; Hydra M2000, M4000; Hydra Pro Super; PowrTwin 12000GHD, 12000GH, 8900GH, 6900GH, 4900GH, 4500, 3500; PowrLiner 8900, 6000, 5000, 4900, 4000; PowrCoat 730, 745, 940, 960, 975; Commander.
Accurate Part Number 944-904 Tungsten Valve Seat.
Related Parts Commonly Serviced Together Valve body (944-020), O-ring (944-004), valve stem stop (944-026), tungsten carbide ball (761-715), copper gasket (945-003), knob assembly (944-024).
Common Problems Solved Loss of system pressure, reduced output, backflow through the valve, and visible wear or pitting on the valve seat surface.
When Replacement Is Recommended Replace if the valve seat shows visible wear, pitting, or damage. The tungsten carbide seat should not require frequent replacement, but if leakage is observed, inspect both the seat and the ball.
Service Guidance The 944/945 Series Relief Valve has a tungsten carbide seat that should not require frequent replacement. The tungsten carbide ball, in normal service, will last a long time because it rotates and wears evenly. If there is leakage, replace the ball. Open the adjustment knob to full counterclockwise position before unthreading the valve seat from the valve body. All non-moving threads must be assembled with Loctite sealant.
OEM & Brand Information Genuine Titan OEM component designed for correct fitment in compatible spray systems.
Commercial Benefits Restores proper valve sealing, prevents backflow, maintains system pressure, and extends bleed valve service life in high-wear applications.

The 944-904 Tungsten Valve Seat is a critical replacement component for contractors who need reliable pressure relief and leak-free system operation. Tungsten carbide is one of the hardest materials used in valve applications, offering exceptional resistance to abrasion, corrosion, and deformation. The 944/945 Series Relief Valve has a tungsten carbide seat that should not require frequent replacement. The tungsten carbide ball, in normal service, will last a long time because it rotates and wears evenly. If there is leakage, replace the ball. If the valve seat shows visible wear, pitting, or damage, replace it with this genuine part to restore proper sealing and ensure safe, reliable pressure relief operation.

FAQ Section

Quick contractor-focused answers for confirming fitment, function, and service value.

Common Questions
What is Titan 944-904 Tungsten Valve Seat used for?

It is a tungsten carbide valve seat that provides a durable sealing surface for the check ball in the bleed valve assembly on Admiral, PowrTwin, PowrLiner, Hydra M, and Hydra Pro spray systems.

Which Titan assemblies use 944-904?

Compatible assemblies include Admiral 944-620 Bleed Valve Assembly; Hydra M2000, M4000; PowrTwin 12000GHD, 12000GH, 8900GH, 6900GH, 4900GH, 4500, 3500; PowrLiner 8900, 6000, 5000, 4900, 4000; PowrCoat 730, 745, 940, 960, 975; and Commander.

What are signs that the valve seat needs replacement?

Common signs include loss of system pressure, reduced output, backflow through the valve, and visible wear or pitting on the valve seat surface. The tungsten carbide seat should not require frequent replacement, but if leakage is observed, inspect both the seat and the ball.

When should the tungsten valve seat be replaced?

Replace if the valve seat shows visible wear, pitting, or damage. The tungsten carbide seat should not require frequent replacement, but if leakage is observed, inspect both the seat and the ball.

Why replace a damaged tungsten valve seat?

Replacement restores proper valve sealing, prevents backflow, maintains system pressure, and extends bleed valve service life in high-wear applications.