Titan 944-028A Bleed Valve Assembly

Titan 944-028A Bleed Valve Assembly

Sourced From:
Titan Tools Inc.

Titan High-Pressure Fluid Control Assembly

The Titan 944-028A Bleed Valve Assembly controls pressure relief, priming and flushing flow on compatible PowrCoat sprayers, helping contractors depressurize the fluid system safely, restore dependable circulation and reduce downtime caused by worn valve components.

Brand: Titan Part Number: 944-028A Type: Bleed Valve Assembly Application: Pressure Relief

Compatibility Table

Detail Information
Brand Titan
Accurate compatible Titan machine(s) PowrCoat 730, 745, 940, 960 and 975; cart and wall-mount models 0533730C/W, 0533745C/W, 0533940C/W, 0533960C/W and 0533975C/W.
Part Number 944-028A
Parts / assemblies serviced with 944-024 knob, 944-020 housing, 944-004 O-ring, 944-026 stop, 761-715 ball, 945-003 gasket and 944-904 seat.
Technical / Commercial Detail Supports priming, flushing and controlled fluid-pressure release.

Replace a leaking, difficult-to-operate or worn bleed valve promptly to maintain safer pressure relief and dependable jobsite startup.

Retail Price: $270.3
You save: $37.57 (13.90%)
Our Price: $232.73
Professional High-Pressure Fluid Control

Maximize Coating Productivity with Titan 944-028A Bleed Valve Assembly Installed

Restore dependable priming, flushing and pressure-relief performance with the 944-028A. This complete bleed valve assembly helps professional crews control return flow, relieve trapped fluid pressure and maintain productive operation across compatible Titan PowrCoat air-powered sprayers.

Controlled Pressure Relief Priming and Flushing Support Complete Valve Assembly Genuine Titan Component
Technical Category Product and Application Details
Product Overview Complete Titan bleed valve assembly designed for the high-pressure filter and return-flow system used on compatible PowrCoat air-powered airless sprayers.
Function Opens the return path during priming, flushing and pressure-relief procedures, then closes to direct pressurized coating material toward the spray hose and gun during application.
Industrial Applications Commercial painting, structural steel finishing, industrial maintenance, protective coatings, equipment refinishing, architectural applications and other high-output airless spraying operations.
Accurate Compatible Titan Machines Titan PowrCoat 730 cart model 0533730C and wall model 0533730W;
Titan PowrCoat 745 cart model 0533745C and wall model 0533745W;
Titan PowrCoat 940 cart model 0533940C and wall model 0533940W;
Titan PowrCoat 960 cart model 0533960C and wall model 0533960W;
Titan PowrCoat 975 cart model 0533975C and wall model 0533975W.
Accurate Part Number Titan 944-028A — bleed valve assembly.
Compatible Parts & Assemblies Mounts to the 1/4-inch NPT female bleed-valve port on the compatible PowrCoat high-pressure filter assembly and operates with the return-tube fitting and bleed hose circuit.
Related Parts Commonly Serviced Together Titan 944-024 knob, 944-020 valve housing, 944-004 O-ring, 944-026 valve stop, 761-715 ball, 945-003 gasket, 944-904 valve seat and 9885639 return-tube fitting.
Common Problems Solved Helps correct material leaking continuously through the bleed hose, incomplete valve shutoff, difficult priming, restricted flushing, slow pressure buildup and pressure loss caused by worn internal valve components.
Use with Coating Systems Intended for compatible PowrCoat pneumatic airless systems handling architectural and industrial coatings. The valve supports circulation of coating material or suitable cleaning solvent through the return circuit.
OEM & Brand Information Genuine Titan replacement assembly engineered for the specified PowrCoat machines, high-pressure filter connection and return-flow configuration.
Commercial Benefits Reliable valve operation supports faster priming, cleaner flushing, controlled pressure relief and fewer interruptions caused by leakage or incomplete shutoff. Replacing the complete assembly also simplifies repairs when several internal components are worn.
Contractor Service Advantage

A worn bleed valve can allow coating material to continue flowing through the return hose after the valve is closed, reducing pressure and disrupting production. Replace damaged seats, seals or the complete assembly promptly, and always complete the full pressure-relief procedure before service.

FAQ Section

Review these contractor-focused answers before ordering or servicing the bleed valve.

Contractor Questions and Answers
Which Titan sprayers use this bleed valve assembly?

It is used on PowrCoat 730, 745, 940, 960 and 975 air-powered airless sprayers in their corresponding cart and wall-mount configurations.

What are the common symptoms of a worn bleed valve?

Typical symptoms include coating continuing to flow from the bleed hose after closing the valve, slow pressure buildup, pressure loss, difficult priming or incomplete shutoff.

Does this valve help with priming and flushing?

Yes. Opening the valve directs material or cleaning solvent through the return circuit, allowing trapped air and residual coating to leave the system during priming and flushing.

Which internal parts should be inspected during service?

Inspect the knob, housing, O-ring, valve stop, ball, gasket and valve seat. Replace components showing scoring, deformation, hardened coating, leakage or sealing-surface damage.

Should the bleed valve alone be used to relieve pressure?

No. Contractors should follow the complete machine pressure-relief procedure, including shutting off the air supply, opening the bleed valve and triggering the grounded spray gun into an appropriate container.