Titan 704-211A Circuit Breaker (Replaces Titan 0551515)

Titan 704-211A Circuit Breaker (Replaces Titan 0551515)

Sourced From:
Titan Tools Inc.

 

OEM Titan Electrical Protection Component

Titan 704-211A Circuit Breaker (replaces Titan 0551515) is an OEM circuit breaker that protects the electrical system from overloads and short circuits, preventing damage to the motor and control circuits on compatible Titan and SprayTECH spray systems.

Brand: Titan Part #: 704-211A Replaces: 0551515 Type: Circuit Breaker

Compatibility Table

Brand Compatible Model Part Number Replaces Technical / Commercial Detail
Titan Advantage 400; Helix FR/VR; Impact 410/440; RentSpray 500 704-211A 0551515 Protects motor and control circuits from overload and short circuits .
Titan 340; 400; 450 704-211A 0551515 Provides overload and short circuit protection .
SprayTECH EPX2155; EPX2255 704-211A 0551515 OEM circuit breaker for compatible SprayTECH systems .

OEM circuit breaker restores reliable overload protection, prevents motor and circuit damage, and maintains safe electrical system operation on compatible spray systems.

$16.4

Titan Electrical Protection Component Replacement

Titan 704-211A Circuit Breaker (Replaces 0551515) for Advantage, Helix, Impact, RentSpray & SprayTECH Systems

Titan 704-211A is an OEM circuit breaker that replaces the original Titan part number 0551515. This electrical protection device is designed to interrupt power when an overload or short circuit occurs, safeguarding the motor and control circuits on compatible spray systems .

OEM: Titan / SprayTECH Part #: 704-211A Replaces: 0551515 Type: Circuit Breaker
Detail Technical / Commercial Information
Product Overview OEM Titan circuit breaker that protects the electrical system from overload and short circuit conditions. Directly replaces original Titan part number 0551515 .
Function Interrupts power when current exceeds the rated limit, stopping power flow to prevent overheating, insulation failure, and potential fire hazards . The breaker can be manually reset once the underlying fault is corrected .
Replacement Indicators Signs that the circuit breaker needs replacement include frequent nuisance tripping under normal load, failure to reset, visible signs of overheating such as discoloration or melting, or the breaker not tripping during a fault .
Troubleshooting If the breaker trips repeatedly after replacement, inspect the power cord, on/off switch, and motor windings for damage that could cause repeated tripping .
Industrial Applications Professional painting, line striping, architectural coatings, and any application requiring reliable electrical circuit protection .
Compatible Titan Models Advantage 400 ; Helix FR ; Helix VR ; Impact 410 ; Impact 440 (service) ; RentSpray 500 ; 340 ; 400 ; 450 .
Compatible SprayTECH Models EPX2155 ; EPX2255 .
Accurate Part Number 704-211A Circuit Breaker (replaces Titan 0551515) .
Related Parts Commonly Serviced Together Power cord, on/off switch, motor windings .
Common Problems Solved Frequent nuisance tripping, failure to reset, visible heat damage, failure to trip during fault, power loss, electrical system failure .
OEM & Brand Information Genuine Titan OEM component designed for correct fitment in compatible Titan and SprayTECH systems .
Commercial Benefits Restores reliable overload protection, prevents motor and circuit damage, reduces downtime from electrical issues, and maintains safe equipment operation .

The 704-211A Circuit Breaker (replaces 0551515) is a practical replacement for contractors who need reliable electrical protection in compatible spray systems. Over time, circuit breakers can wear out, becoming prone to nuisance tripping or failing to trip altogether . A faulty breaker can lead to motor damage, control circuit failure, or fire hazards . If you experience frequent tripping under normal load, failure to reset, or visible heat damage, replace the breaker immediately . After replacement, if the breaker continues to trip, inspect the power cord, on/off switch, and motor windings for damage that could cause excessive current draw . Using the correct OEM replacement maintains the original safety specifications of the equipment .

FAQ Section

Quick contractor-focused answers for confirming fitment, function, and service value.

Common Questions
What is Titan 704-211A Circuit Breaker used for?

It protects the electrical system from overload and short circuit conditions, preventing damage to the motor and control circuits .

Which Titan part number does 704-211A replace?

The 704-211A circuit breaker directly replaces the original Titan part number 0551515 .

Which machines use 704-211A?

Compatible models include Titan Advantage 400, Helix FR/VR, Impact 410/440, RentSpray 500, 340, 400, 450, and SprayTECH EPX2155/EPX2255 .

What are the signs that the circuit breaker needs replacement?

Common signs include frequent nuisance tripping under normal load, failure to reset, visible heat damage such as discoloration or melting, or the breaker not tripping during a fault .

Why replace a damaged circuit breaker?

Replacement restores reliable overload protection, prevents motor and circuit damage, reduces downtime from electrical issues, and maintains safe equipment operation .