Please wait while we process your order...

Product successfully added to your cart.
Placeholder Image

Quantity in Cart: 1


Continue Shopping Shopping Cart
Item removed from Cart
X
 
×
Titan 700-926 Piston Lube

Titan 700-926 Piston Lube

Sourced From:
Titan Tools Inc.

PowrLiner part 700-926 is a Piston Lube used to lubricate the piston and cylinder assembly in fluid pumps. When lubrication is insufficient or the lube is contaminated, piston wear increases and seal life decreases. This replacement lubricant restores proper piston protection and pump efficiency on compatible PowrLiner, PowerBeast, Performer, Impact, Hydra, Epic, Elite, Airless Sprayer, and other units.

Part Number 700-926
Part Description Piston Lube
Brand PowrLiner
Fits PowrLiner 3100, PowerBeast, Power Beast, Performer 640 i Airless Sprayer, Impact 1640, Impact 540 Airless Sprayer operation, Impact 440 service, Impact 440 operation, Impact 410, Impact 400 Airless Sprayer, Impact 340, hydrax 4540 - 7230, Hydra M and Hydra Epic, 660ex, Pro 2000_4000, Hydr M and Hydra Pro Super, Epic 1200 HPG, Epic 690 HPG, Epic 660HPX, Epic 447HPX, Epic 447ex, Elite G40, Elite E55, Elite E15, Elite 3000, Elite 2000, Airless Sprayer1200 GXC, 0537810I_GB_D_F (1), 0528925N_2000_4000, 1100 XC Airless Sprayer, 690 GXC Airless Sprayer, 660 XC Airless Sprayer, 550 XC Airless Sprayer, 440 XC Airless_Sprayer, 330 Airless Sprayer
Condition New

Retail Price: $43.2
You save: $3.28 (7.59%)
Our Price: $39.92

 

Piston Lube for PowrLiner, PowerBeast, Performer, Impact, Hydra, Epic, Elite, and Airless Sprayer Series Equipment

The PowrLiner 700-926 Piston Lube is a specialized lubricant designed to reduce friction between the piston and cylinder wall in fluid pumps, extending component life and maintaining pump efficiency. On compatible equipment including the PowrLiner 3100, PowerBeast, Power Beast, Performer 640 i Airless Sprayer, Impact 1640, 540 Airless Sprayer operation, 440 service, 440 operation, 410, 400 Airless Sprayer, 340, hydrax 4540-7230, Hydra M and Hydra Epic, 660ex, Pro 2000_4000, Hydr M and Hydra Pro Super, Epic 1200 HPG, 690 HPG, 660HPX, 447HPX, 447ex, Elite G40, E55, E15, 3000, 2000, Airless Sprayer1200 GXC, 0537810I_GB_D_F (1), 0528925N_2000_4000, 1100 XC, 690 GXC, 660 XC, 550 XC, 440 XC Airless_Sprayer, and 330 Airless Sprayer, proper piston lubrication is critical for preventing scoring, reducing heat generation, and ensuring smooth pump operation. Without adequate lubrication, the piston can gall against the cylinder wall, causing rapid wear, loss of pressure, and eventual pump failure. Contaminated or degraded lube loses its film strength and protective properties. Replacing old or contaminated piston lube restores proper film strength, reduces operating temperature, and extends the service life of pistons, packings, and cylinders. This genuine PowrLiner replacement lubricant meets original equipment specifications for viscosity, film strength, temperature range, and compatibility with pump materials. When applying piston lube, follow the equipment manual's recommended quantity and interval. Do not over-lubricate, as excess lube can contaminate coating material. Users should always verify compatibility with their specific model and revision before use. Regular piston lube inspection and replacement should be part of preventive maintenance programs for professional spray equipment.

Service Guidance: If the pump exhibits increased operating temperature, reduced pressure output, unusual noise, or visible piston wear, inspect and replace the piston lube before returning the unit to service.

What it does and when to replace it

What the Piston Lube does
seventyReduces operating temperature of pump assembly
Friction reduction Minimizes contact friction between piston and cylinder
Wear protection Prevents scoring, galling, and premature piston failure
Heat dissipation
When replacement is recommended
Contaminated lube Lube appears dark, gritty, or mixed with coating material
Increased pump heat Pump runs hotter than normal during operation
Pressure loss Reduced output pressure not caused by other components
Scheduled maintenance Per manufacturer recommended service interval

Compatibility

PowrLiner part 700-926 is compatible with the following equipment. Always confirm fitment using the correct parts diagram for your exact model and revision.

Compatible Models Component
PowrLiner 3100, PowerBeast, Power Beast, Performer 640 i Airless Sprayer Piston Lube
Impact 1640, 540 Airless Sprayer operation, 440 service, 440 operation, 410, 400 Airless Sprayer, 340 Piston Lube
hydrax 4540-7230, Hydra M and Hydra Epic, 660ex, Pro 2000_4000, Hydr M and Hydra Pro Super Piston Lube
Epic 1200 HPG, 690 HPG, 660HPX, 447HPX, 447ex, Elite G40, E55, E15, 3000, 2000 Piston Lube
Airless Sprayer1200 GXC, 0537810I_GB_D_F (1), 0528925N_2000_4000, 1100 XC, 690 GXC, 660 XC, 550 XC, 440 XC Airless_Sprayer, 330 Airless Sprayer Piston Lube

Related parts commonly serviced together

Pump performance problems are often caused by more than one component. When servicing the piston lube, these parts are commonly inspected at the same time.

Piston and cylinder

Inspect for scoring, galling, or excessive wear when changing lube.

Piston packings and seals

Worn packings can allow material to contaminate the piston lube.

Lube reservoir and fittings

Damaged fittings or clogged passages prevent proper lube delivery.

Frequently Asked Questions

It is a Piston Lube used to lubricate the piston and cylinder assembly in fluid pumps on compatible PowrLiner, PowerBeast, Performer, Impact, Hydra, Epic, Elite, and Airless Sprayer equipment.

Common signs include lube that appears dark, gritty, or mixed with coating material, increased pump operating temperature, reduced pressure output not caused by other components, or when scheduled maintenance intervals are reached.

PowrLiner 3100, PowerBeast, Power Beast, Performer 640 i, Impact 1640, 540 operation, 440 service, 440 operation, 410, 400, 340, hydrax 4540-7230, Hydra M and Epic, 660ex, Pro 2000_4000, Hydr M and Pro Super, Epic 1200 HPG, 690 HPG, 660HPX, 447HPX, 447ex, Elite G40, E55, E15, 3000, 2000, Airless Sprayer1200 GXC, 0537810I_GB_D_F (1), 0528925N_2000_4000, 1100 XC, 690 GXC, 660 XC, 550 XC, 440 XC, 330 Airless Sprayer.

Consult your equipment manual for specific intervals. Generally, piston lube should be inspected every 50-100 operating hours and replaced when contaminated or at manufacturer-recommended service intervals.