Please wait while we process your order...

Product successfully added to your cart.
Placeholder Image

Quantity in Cart: 1


Continue Shopping Shopping Cart
Item removed from Cart
X
 
×
Titan 2442149 Gun Extension

Titan 2442149 Gun Extension

Sourced From:
Titan Tools Inc.

Part number 2442149 is a Gun Extension designed for use with compatible Hydra X high-pressure airless sprayer systems. This rigid extension tube enables operators to safely reach elevated or distant surfaces without repositioning equipment, improving job site efficiency and application precision.

Part Number 2442149
Part Description Gun Extension
Fits hydrax 4540 - 7230
Condition New

Retail Price: $86.4
You save: $7.17 (8.30%)
Our Price: $79.23

Gun Extension for Hydra X 4540 and 7230 Airless Sprayers

Part number 2442149 is a Gun Extension, a precision-engineered rigid tube assembly specifically designed for the Titan Hydra X 4540 and Hydra X 7230 high-pressure, gas-powered airless sprayers. These professional units deliver up to 7,250 PSI operating pressure and are capable of processing highly viscous coating materials up to 65,000 mPas, making them ideal for large-scale commercial and industrial applications including heavy-duty protective coatings, roof sealing, and corrosion control. The gun extension provides operators with critical extended reach, enabling safe and efficient spraying of elevated structures and distant surfaces without the need for ladders, scaffolding, or frequent equipment repositioning.

The Hydra X series service and operation manuals contain specific safety warnings regarding accessories used with these high-pressure systems. All accessories, including spray tips, guns, extensions, and hoses, must be rated at or above the maximum operating pressure range of the sprayer. This gun extension is manufactured to meet or exceed the pressure requirements of both the 4,500 PSI 4540 model and the 7,250 PSI 7230 model. The extension features precision-machined threads at both ends for secure, leak-proof attachment to the spray gun and tip assembly, with an internal bore diameter carefully engineered to minimize pressure drop and maintain full atomization performance at the spray tip.

Constructed from high-strength materials with a durable, corrosion-resistant finish, this gun extension withstands the extreme operating pressures and harsh environmental conditions encountered in professional coating applications. The rigid design maintains consistent spray pattern orientation and standoff distance, improving finish quality and transfer efficiency. By eliminating the need for operators to work from heights, the extension significantly improves job site safety while reducing worker fatigue and increasing productivity on large-scale projects. Regular inspection for cracks, thread damage, or material buildup is essential for safe operation.

Service Guidance: Inspect the gun extension before each use for cracks, dents, thread damage, or internal material buildup. Verify that all connections are clean and undamaged. Apply PTFE tape to male threads if required. Ensure the extension is properly rated for your specific Hydra X model's maximum operating pressure. Never use the extension as a handle to lift or pull the sprayer.

What it does and when to replace it

What the gun extension does
Extended Reach Enables spraying of elevated and distant surfaces without ladders or scaffolding
Pressure Rating Engineered for full operating pressure of Hydra X 4540 and 7230 models
Application Efficiency Reduces equipment repositioning and improves job site safety
When replacement is recommended
Physical Damage Tube is bent, dented, cracked, or has visible deformation
Thread Damage Connecting threads are stripped, crossed, or excessively worn
Pressure Leakage Fluid seeps from extension body or connection points during operation
Internal Wear Erosion or material buildup restricts flow and affects spray pattern

Compatibility

Part number 2442149 is specifically designed for the Titan Hydra X 4540 and Hydra X 7230 high-pressure airless sprayer systems. Both models are covered under the same service and operation manuals, share common fluid section architecture, and utilize identical accessory thread specifications. The 4540 model operates at 4,500 PSI, while the 7230 model delivers up to 7,250 PSI. This gun extension is a model-specific component engineered for the pressure requirements and connection standards of these professional sprayer systems. Always confirm fitment using the correct parts diagram for your exact model and serial number.

Compatible Models Component
hydrax 4540 - 7230 Gun Extension

Related parts commonly serviced together

The gun extension is an accessory that connects directly to the spray gun and tip assembly. When purchasing or servicing this component, these related parts are often ordered at the same time.

High-Pressure Spray Gun

The professional airless spray gun that attaches to the extension. Must be rated for Hydra X operating pressures.

Spray Tip and Tip Guard

The tip assembly mounts at the end of the extension. Select appropriate tip size for material and pressure requirements.

Swivel Connector

A rotating fitting that reduces hose twisting and improves maneuverability when using longer extensions.

Frequently Asked Questions

It is a Gun Extension, a rigid tube assembly that attaches to the spray gun to extend reach for elevated and distant spraying applications on Titan Hydra X 4540 and Hydra X 7230 airless sprayer systems.

This gun extension is engineered to meet or exceed the maximum operating pressure of both Hydra X models: 4,500 PSI for the 4540 and 7,250 PSI for the 7230. The Hydra X service manual explicitly states that all accessories used with these sprayers must be rated at or above the unit's maximum operating pressure range. Always verify the pressure rating marked on the component before use.

This gun extension is specifically designed for the Hydra X 4540 and 7230 models and is pressure-rated for these high-output systems. While it may physically attach to other Titan spray guns with compatible threads, using it on systems exceeding its rated pressure is dangerous. Conversely, using it on lower-pressure systems is acceptable but not its intended application. Always verify compatibility with your specific model's parts manual.

Before each use, visually inspect the entire extension for cracks, dents, bending, or thread damage. Check for material buildup inside the bore and clean with appropriate solvent and a soft brush. Never use metal tools that could scratch the internal surface. Before connecting, ensure threads are clean and undamaged. Apply PTFE tape clockwise to male threads, leaving the first thread free. Tighten securely with wrenches on both connection hexes; do not overtighten. Test at low pressure before full operation.