Please wait while we process your order...

Product successfully added to your cart.
Placeholder Image

Quantity in Cart: 1


Continue Shopping Shopping Cart
Item removed from Cart
X
 
×
Titan 2442148 Gun Extension

Titan 2442148 Gun Extension

Sourced From:
Titan Tools Inc.

Part number 2442148 is a Gun Extension that extends the reach of the spray gun on compatible Hydra X sprayer systems. This rigid extension tube enables operators to access elevated or distant surfaces without the need for ladders or scaffolding, improving safety and application efficiency.

Part Number 2442148
Part Description Gun Extension
Fits hydrax 4540 - 7230
Condition New

Retail Price: $76
You save: $6.31 (8.30%)
Our Price: $69.69

Gun Extension for Hydra X 4540 and 7230 Sprayers

Part number 2442148 is a Gun Extension, a precision-engineered rigid tube assembly specifically designed for the Titan Hydra X 4540 and Hydra X 7230 high-flow, gas-powered roofing and protective coatings sprayers. These professional units are capable of supporting up to six guns simultaneously at pressures up to 7,200 psi, making them ideal for large-scale commercial and industrial coating applications. The gun extension provides operators with additional reach to safely and efficiently spray elevated surfaces, overhead structures, and distant areas without repositioning equipment or working from heights.

Constructed from high-strength materials with a wear-resistant finish, this extension tube is engineered to withstand the extreme operating pressures of the Hydra X series while maintaining fluid integrity and spray pattern consistency. The precision-machined threaded connections at both ends provide secure, leak-proof attachment to the spray gun and tip assembly. The internal bore diameter is carefully calibrated to minimize pressure drop over the extension length, ensuring full system pressure is delivered to the spray tip for optimal atomization of heavy-bodied coatings such as asphalt emulsions, acrylics, and silicone roof coatings.

The Hydra X service documentation confirms that all accessories used with these sprayers, including extensions, must be rated at or above the maximum operating pressure range of the unit. This gun extension is manufactured to meet or exceed the pressure requirements of both the 4,500 psi 4540 model and the 7,200 psi 7230 model. By extending the operator's reach, this accessory reduces the need for ladders and scaffolding, significantly improving job site safety while increasing productivity. The extension also facilitates precise coating application in confined spaces and allows operators to maintain proper standoff distance for optimal pattern development.

Service Guidance: Before each use, inspect the extension for cracks, thread damage, or material buildup. Verify that all connections are clean and undamaged. Apply PTFE tape to male threads if required. Ensure the extension is properly rated for the maximum operating pressure of your specific Hydra X model. Never use extension as a handle to lift or pull the sprayer.

What it does and when to replace it

What the gun extension does
Extended Reach Enables spraying of elevated and distant surfaces without ladders
Pressure Rating Engineered for full operating pressure of Hydra X 4540 and 7230 models
Application Efficiency Reduces equipment repositioning and improves job site safety
When replacement is recommended
Physical Damage Tube is bent, dented, or cracked
Thread Damage Connecting threads are stripped, crossed, or worn
Leakage Fluid seeps from extension body or connection points
Internal Wear Erosion or material buildup restricts flow and affects pattern

Compatibility

Part number 2442148 is specifically designed for the Titan Hydra X 4540 and Hydra X 7230 high-flow, gas-powered roofing and protective coatings sprayers. These professional units share common spray gun thread specifications and pressure requirements. The Hydra X service manual includes a comprehensive accessories section, and this gun extension is a model-specific component engineered for the operating pressure range and connection standards of these particular sprayer systems. Always confirm fitment using the correct parts diagram for your exact model.

Compatible Models Component
hydrax 4540 - 7230 Gun Extension

Related parts commonly serviced together

The gun extension is an accessory that connects to the spray gun and tip assembly. When servicing or purchasing this component, these related parts are often ordered at the same time.

Spray Gun Assembly

The professional airless spray gun that attaches to the extension. Must be rated for Hydra X operating pressures.

Tip Guard and Tip

The spray tip assembly mounts at the end of the extension. Choose appropriate tip size for material and pressure.

Swivel Connector

A rotating fitting that reduces hose twisting and improves maneuverability when using extensions.

Frequently Asked Questions

It is a Gun Extension, a rigid tube assembly that attaches to the spray gun to extend reach for elevated and distant spraying applications on Titan Hydra X 4540 and Hydra X 7230 sprayer systems.

This gun extension is engineered to meet or exceed the maximum operating pressure of both Hydra X models: 4,500 psi for the 4540 and 7,200 psi for the 7230. All accessories used with these sprayers must be rated at or above the unit's maximum operating pressure range. Always verify the pressure rating marked on the component before use.

This gun extension is specifically designed for the Hydra X 4540 and 7230 models. While it may physically attach to other Titan spray guns, it is pressure-rated specifically for these high-output units. Using this extension on lower-pressure systems is acceptable, but using it on systems exceeding its rated pressure is dangerous. Always verify compatibility with your specific model's parts manual.

Ensure threads are clean and undamaged before assembly. Apply PTFE tape clockwise to male threads, leaving the first thread free to prevent tape fragments from entering the fluid stream. Tighten securely with wrenches on both connection hexes; do not overtighten. Inspect seals and O-rings for damage and replace if necessary. Test connection at low pressure before full operation.