Please wait while we process your order...

Product successfully added to your cart.
Placeholder Image

Quantity in Cart: 1


Continue Shopping Shopping Cart
Item removed from Cart
X
 
×
Titan 0347706A Swivel joint Assembly (replaces Titan 580-530)

Titan 0347706A Swivel joint Assembly (replaces Titan 580-530)

Sourced From:
Titan Tools Inc.

0347706A Swivel Joint Assembly is a rotating coupling component used in the fluid delivery system of compatible airless sprayers. This assembly allows the spray hose to pivot freely, reducing operator fatigue and preventing hose kinking during use. A properly functioning swivel joint enables smooth movement and consistent material flow. This assembly restores full swivel articulation and leak-free operation on compatible units. It replaces Titan 580-530.

Part Number 0347706A
Part Description Swivel Joint Assembly
Brand Airless
Cross Reference Replaces Titan 580-530
Fits Airless LX 50; Advantage GPX 33
Condition New

Retail Price: $76.6
You save: $6.36 (8.30%)
Our Price: $70.24

 

Swivel Joint Assembly for Airless LX 50 and Advantage GPX 33 Sprayers

The 0347706A Swivel Joint Assembly is a replacement component designed for the fluid delivery system on Airless LX 50 and Advantage GPX 33 airless sprayers. This assembly incorporates a rotating coupling mechanism that allows the spray hose to pivot freely at the connection point, providing enhanced maneuverability during spraying operations. The swivel joint reduces strain on the hose, prevents twisting and kinking, and allows the operator to move naturally without fighting hose tension. This component is critical for maintaining comfortable operation during extended spraying sessions and for protecting the hose from premature wear caused by twisting stress. The assembly is manufactured as a direct replacement for Titan 580-530, offering an equivalent alternative for maintaining these sprayer models.

Swivel joints endure constant rotational movement and exposure to pressurized coating materials. Over time, internal seals can wear, bearings may develop play, or the joint may begin to leak under pressure. A failing swivel joint may exhibit fluid seepage at the connection point, increased resistance to rotation, or stiffness that makes hose movement difficult. In some cases, a seized or leaking swivel can cause the hose to twist unexpectedly, creating operator fatigue or interrupting material flow. Replacing the swivel joint assembly restores smooth articulation, eliminates leaks, and returns the maneuverability expected of properly functioning equipment. This assembly includes all necessary internal components for a complete replacement, ensuring reliable performance when installed correctly.

Service Guidance: If the swivel joint exhibits fluid leakage, becomes difficult to rotate, or shows signs of material seepage around the swivel housing, replace the assembly to restore proper function and prevent further damage to the hose or sprayer connection.

What it does and when to replace it

What the swivel joint assembly does
Rotational freedom Allows the spray hose to pivot freely, reducing operator fatigue
Hose protection Prevents kinking, twisting, and premature wear of the spray hose
Leak-free connection Maintains a sealed coupling that withstands high operating pressures
When replacement is recommended
Fluid leakage Material seeps from the swivel housing during operation
Stiff rotation Swivel does not turn freely or requires excessive force to pivot
Excessive play Noticeable looseness or wobble in the swivel connection
Hose twisting Spray hose twists or kinks despite proper handling

Compatibility

The 0347706A Swivel Joint Assembly is compatible with the following airless sprayers. This assembly replaces Titan 580-530. Always confirm fitment using the correct parts diagram for your exact model and revision.

Model Component
Airless LX 50 Swivel Joint Assembly
Advantage GPX 33 Swivel Joint Assembly

Related parts commonly serviced together

Fluid delivery system issues often involve multiple components. When servicing the swivel joint, these parts are frequently inspected or replaced at the same time.

Spray hose

A worn or damaged hose can cause connection issues and may need replacement alongside the swivel joint.

Hose couplings / fittings

Damaged or worn coupling threads can prevent proper sealing and contribute to leaks.

Spray gun inlet connection

The gun inlet threads should be inspected for damage when replacing the swivel assembly.

Frequently Asked Questions

The swivel joint allows the spray hose to rotate freely at the connection point, reducing hose twisting and kinking while improving operator maneuverability. It also provides a leak-free seal that withstands the high pressures of airless spraying.

Common signs include fluid leaking from the swivel housing, stiffness or grinding when rotating the joint, excessive looseness or wobble in the connection, and the spray hose twisting or kinking despite proper handling.

This swivel joint assembly is compatible with Airless LX 50 and Advantage GPX 33 sprayers. It replaces Titan 580-530. Always verify fitment using the correct parts diagram for your specific model.

Swivel joints are typically replaced as complete assemblies. Internal seals and bearings are precision components that require specialized tools for service. Replacing the full assembly ensures proper sealing, smooth rotation, and reliable performance under pressure.